Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Optical characterization of a new photodiode array ocular fluorometer
Publication

Publications

Optical characterization of a new photodiode array ocular fluorometer

Title
Optical characterization of a new photodiode array ocular fluorometer
Type
Article in International Conference Proceedings Book
Year
1996
Authors
Domingues, JPP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pinto, FAM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Correia, CMBA
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
CunhaVaz, JG
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Conference proceedings International
Pages: 110-118
Conference on Optical and Imaging Techniques for Biomonitoring II
VIENNA, AUSTRIA, SEP 09-10, 1996
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-001-FGV
Abstract (EN): Ocular Fluorometry has been considered an important technique in ophthalmology diagnosis and research. It consists in the application of a fluorometric method for determination of some important physiologic parameters in the eye in a non-invasive way(1,2,3). The need for new instrumentation for ocular fluorometry has been reported on the literature(4) - there is an ocular fluorometer commercially available, the Fluorotron Master, FM(3,5), but lack of axial resolution and high cost call for new instruments based on modern solid state sensors. Also the field of application of this technique is broadening due to availability of new tracers and exploitation of native fluorescence of ocular tissues and fluids (for which the FM is not fitted). In this paper we present the optics of a new instrument (ocular fluorometer(1)) and report most of the tests to completely characterize the optical parameters of this fluorescence imaging system. Optical amplification, image spatial energy distribution over the detector - a Linear array of photodiodes, quantification and correction of slit-lamp angle, excitation and emission filter characteristics are some of the parameters that must be evaluated for a reliable interpretation of results. With a complete fluorometer characterization both in terms of performance parameters related mainly with the detector (linearity, sensitivity, reproducibility) in vitro and in vivo(6) and in terms of optical system regarding the properties of the image obtained and possible aberrations correction by software we can perform reliable clinical evaluations of normal or abnormal situations in order to give the physician valid data he can store and recall for future reference.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 9
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-06 at 11:34:46 | Privacy Policy | Personal Data Protection Policy | Whistleblowing