Fault Ratio Enriched Anomaly Detection and Discrimination in a PV System Using a Fault Detector-Array Combiner Box

Title
Fault Ratio Enriched Anomaly Detection and Discrimination in a PV System Using a Fault Detector-Array Combiner Box
Type
Article in International Scientific Journal
Year
2024
Authors
Ram, JP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Kim, YJ
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 39
Pages: 914-929
ISSN: 0885-8969
Publisher: IEEE
Indexing
Other information
Authenticus ID: P-010-MJA
Abstract (EN): Photovoltaic (PV) power generation is susceptible to various permanent electrical faults, including line-to-line (LL), line-to-ground (LG), and open-circuit (OC) faults. Additionally, non-catastrophic, temporary shading faults can also occur. These faults can lead to changes in the I-V characteristics and cause a shift in the maximum power point (MPP). Permanent faults such as LL/LG and OC can significantly alter the array's open circuit voltage and short circuit current. This research proposes a novel sensor-less approach for detecting, discriminating, and locating different faults in a PV array. The proposed approach utilizes the mandatory Maximum Power Point Tracking (MPPT) reference to assess the likelihood of fault occurrence. It then analyzes the altered I-V characteristics to discriminate and locate the fault location within the PV array. To facilitate fault detection and categorization, a new Fault Detector-Array Combiner Box (FD-ACB) with power electronic switches has been developed. The effectiveness of the proposed algorithm is evaluated using a test setup consisting of three 4x4 sub-arrays. Detailed case studies involving LL/LG, OC, and shade faults are presented. The results demonstrate that the sensor-less FD-ACB setup has the potential to find (i) undetected and undiagnosed LL/LG and OC faults, (ii) discriminate shade and permanent faults, and (iii) locate the faulty PV sub-array vulnerable to permanent faults.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 16
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Reactive power response of wind generators under an incremental network-loss allocation approach (2008)
Article in International Scientific Journal
P. M. de Oliveira de Jesus; Edgardo D. Castronuovo; M. T. Ponce de Leão
Multiobjective design optimization of generalized multilayer multiphase ac winding (2019)
Article in International Scientific Journal
Silva, AM; Ferreira, FJTE; Cistelecan, MV; Antunes, CH
Influence of the Variable Speed Wind Generators in Transient Stability Margin of the Conventional Generators Integrated in Electrical Grids (2004)
Article in International Scientific Journal
Marcus Vinícius; João Peças Lopes; Ubiratan Bezerra; Hans Zürn; Rogério Almeida
Data-Driven Modeling and Optimal Control of Hydrogen Energy Storage for Frequency Regulation (2023)
Article in International Scientific Journal
Lee, GH; Park, JY; Ban, J; Kim, YJ; Catalao, JPS
An instrument for measurement of induction motor drives based on phasor and modelling techniques (1999)
Article in International Scientific Journal
araujo, re; Diamantino Freitas; goncalves, jj
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-19 at 19:28:33 | Privacy Policy | Personal Data Protection Policy | Whistleblowing