Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Sensitive sequential injection determination of naproxen based on interaction with β-cyclodextrin
Publication

Publications

Sensitive sequential injection determination of naproxen based on interaction with β-cyclodextrin

Title
Sensitive sequential injection determination of naproxen based on interaction with β-cyclodextrin
Type
Article in International Scientific Journal
Year
2005
Authors
Eftychia-Pavlina Zisiou
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Paula C.A.G. Pinto
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
M. Lúcia M.F.S. Saraiva
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Christophe Siquet
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: TalantaImported from Authenticus Search for Journal Publications
Vol. 68 No. 2
Pages: 226-230
ISSN: 0039-9140
Publisher: Elsevier
Indexing
Publicação em ISI Web of Science ISI Web of Science
Scientific classification
FOS: Medical and Health sciences > Other medical sciences
CORDIS: Health sciences
Other information
Resumo (PT): A sensitive sequential injection analysis (SIA) methodology for the fluorimetric determination of naproxen is proposed. The developed automatic analytical procedure is based on the complexation of naproxen with β-cyclodextrin (β-CD) yielding an enhanced fluorimetric signal (λex = 280 nm, λem = 356 nm). Linear calibration plots were obtained for naproxen concentrations up to 1 × 10−5 mol l−1. The developed methodology exhibited a good precision, with a R.S.D. < 2.1% (n = 15). The detection limit of the determination was 1.9 × 10−7 mol l−1 with a sampling rate of about 70 h−1. The automatic method was applied to the determination of naproxen in pharmaceutical formulations. The obtained results were compared with those furnished by the reference procedure and the relative deviations were lower than 3.6%. No interference was found from the excipients usually used in solid pharmaceutical formulations. <br> <br> Keywords: SIA; Fluorescence; β-Cyclodextrin; Naproxen <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6THP-4GX6HTW-1&_user=2460038&_coverDate=12%2F15%2F2005&_rdoc=13&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235288%232005%23999319997%23610440%23FLA%23display%23Volume)&_cdi=5288&_sort=d&_docanchor=&_ct=51&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=1f0c87110eca74ededdebb718375bc03"> Texto integral</a> <br> <br>
Abstract (EN): A sensitive sequential injection analysis (SIA) methodology for the fluorimetric determination of naproxen is proposed. The developed automatic analytical procedure is based on the complexation of naproxen with β-cyclodextrin (β-CD) yielding an enhanced fluorimetric signal (λex = 280 nm, λem = 356 nm). Linear calibration plots were obtained for naproxen concentrations up to 1 × 10−5 mol l−1. The developed methodology exhibited a good precision, with a R.S.D. < 2.1% (n = 15). The detection limit of the determination was 1.9 × 10−7 mol l−1 with a sampling rate of about 70 h−1. The automatic method was applied to the determination of naproxen in pharmaceutical formulations. The obtained results were compared with those furnished by the reference procedure and the relative deviations were lower than 3.6%. No interference was found from the excipients usually used in solid pharmaceutical formulations. <br> <br> Keywords: SIA; Fluorescence; β-Cyclodextrin; Naproxen <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6THP-4GX6HTW-1&_user=2460038&_coverDate=12%2F15%2F2005&_rdoc=13&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235288%232005%23999319997%23610440%23FLA%23display%23Volume)&_cdi=5288&_sort=d&_docanchor=&_ct=51&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=1f0c87110eca74ededdebb718375bc03"> Full text</a> <br> <br>
Language: Portuguese
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis (2016)
Another Publication in an International Scientific Journal
Couto, RAS; Lima, JLFC; M. Beatriz Q. Garcia
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Flow injection based methods for fast screening of antioxidant capacity (2009)
Another Publication in an International Scientific Journal
Luis M Magalhaes; Miguel Santos; Marcela A Segundo; Salette Reis; Jose L F C Lima
Extraction and preconcentration techniques for chromatographic determination of chlorophenols in environmental and food samples (2012)
Another Publication in an International Scientific Journal
Paulo de Morais; Teodor Stoichev; Clara C P Basto; Teresa T S D Vasconcelos

See all (193)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-14 at 16:37:09 | Privacy Policy | Personal Data Protection Policy | Whistleblowing