Abstract (EN):
Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for the column design for any particular type of packing and contaminant avoiding the necessity of a pre-defined diameter used in the classical approach. It also renders unnecessary the employment of the graphical Eckert generalized correlation for pressure drop estimates. The hydraulic features are previously chosen as a project criterion and only afterwards the mass transfer phenomena are incorporated, in opposition to conventional approach. The design procedure was translated into a conventional algorithm using C++ as programming language.
Language:
Portuguese
Type (Professor's evaluation):
Scientific
Contact:
2nd Meeting on Numerical Methods for Differential Equations
No. of pages:
10