Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Coalescence of two gas slugs rising in a co-current flowing liquid in vertical tubes
Publication

Publications

Coalescence of two gas slugs rising in a co-current flowing liquid in vertical tubes

Title
Coalescence of two gas slugs rising in a co-current flowing liquid in vertical tubes
Type
Article in International Scientific Journal
Year
1998
Authors
Pinto, AMFR
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Pinheiro, MNC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 53 No. 13
Pages: 2973-2983
ISSN: 0009-2509
Publisher: Elsevier
Indexing
Publicação em ISI Web of Science ISI Web of Science
COMPENDEX
Scientific classification
FOS: Engineering and technology > Chemical engineering
Other information
Authenticus ID: P-001-7B5
Abstract (EN): An experimental study is presented about the interaction between two slugs rising through a co-current flowing liquid in vertical tubes with 22, 32 and 52 mm internal diameters. For the conditions studied the liquid flow pattern in the wake of the slugs was turbulent and the main liquid flow regime was either laminar or turbulent. When the liquid flow regime is turbulent the minimum distance between slugs above which there is no interaction is about 5D. For lower distances the slugs coalesce during their rise. When the liquid flow regime is laminar two different situations are observed: -if the ratio between the average velocity in the full developed film around the slug and the average velocity in the main liquid is greater than 25, coalescence between slugs is observed. The minimum distance between slugs above which there is no interaction is about 10D; -if the value of that ratio is lower than 25 and the initial distance between slugs is greater than the wake length of the leading slug, the distance between slugs increases during their rising in the column and slugs coalescence is not observed. This behaviour has never been referred in the literature. The wake length is found to be 5D whatever is the main liquid flow regime.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 11
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

On the interaction of Taylor bubbles rising in two-phase co-current slug flow in vertical columns: turbulent wakes (2001)
Article in International Scientific Journal
Pinto, AMFR; Pinheiro, MNC; Campos, JBL
Experimental study on the transition in the velocity of individual Taylor bubbles in vertical upward co-current liquid flow (2005)
Article in International Scientific Journal
Pinto, AMFR; Pinheiro, MNC; Nogueira, S; Ferreira, VD; Campos, JBLM

Of the same journal

MASS-TRANSFER TO LARGE PARTICLES IN FLUIDIZED-BEDS OF SMALLER PARTICLES - COMMENT (1986)
Another Publication in an International Scientific Journal
decarvalho, jrfg; coelho, man
2 SOLUTION METHODS FOR HYPERBOLIC SYSTEMS OF PARTIAL-DIFFERENTIAL EQUATIONS IN CHEMICAL-ENGINEERING (1991)
Article in International Scientific Journal
José Miguel Loureiro; Alírio Rodrigues
Wrong-way behavior in packed-bed reactors with "large-pore" catalysts (1994)
Article in International Scientific Journal
Almeida Costa, CA; Quinta Ferreira, RMQ; Alírio Rodrigues

See all (222)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-30 at 05:34:40 | Privacy Policy | Personal Data Protection Policy | Whistleblowing