Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Indoor Air Quality at Portuguese Firehouses
Publication

Publications

Indoor Air Quality at Portuguese Firehouses

Title
Indoor Air Quality at Portuguese Firehouses
Type
Chapter or Part of a Book
Year
2024
Authors
Esteves F.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vaz J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Costa S.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Alves M.J.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Madureira J.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Barros B.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernandes A.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teixeira J.P.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Morais S.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Indexing
Publicação em Scopus Scopus - 0 Citations
Scientific classification
CORDIS: Natural sciences > Environmental science
Other information
Authenticus ID: P-00Z-EXH
Abstract (EN): This work assessed firefighters¿ exposure to gases pollutants in non- fire work settings during the pre-fire season as a baseline for the respective occupational exposure characterization. Indoor air sampling (total volatile organic compounds¿TVOCs, ozone-O3, and carbon di oxide-CO2) was conducted for two weeks in the pre-fire season of 2021 in seven firehouses (FH1¿FH7) situated in the north-interior of Portugal. The result showed that across all FH, TVOCs highly varied with observed levels of 180 ¿g m¿3 and 11.5 mg m¿3 (overall median of 1.86 mg m¿3). Furthermore, at all FH, the observed levels highly exceeded (1.5¿6.6 times) the Portuguese protective thresholds of 600 ¿g m¿3 for indoor air quality in public buildings. On the contrary, the indoor ozone concentrations (range: 23¿80 ¿g m¿3; median 60 ¿g m¿3) and CO2 (range 800¿1160 mg m-3: median 924 mg m¿3) were relatively low and in accordance with existing national standards. While the associations between the pollutants were low¿moderate (|rs|= 0.030¿0.679) to better identify the respective indoor emission sources, quantification of specific VOC compounds/classes is required in future studies. © The Author(s), under exclusive license to Springer Nature Switzerland AG 2024.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 9
Documents
We could not find any documents associated to the publication with allowed access.
Related Publications

Of the same book

Indoor Air Quality in Fitness Centers with/without the Restrictions of COVID-19 (2024)
Chapter or Part of a Book
Klara Slezakova; Maria do Carmo Pereira; Cátia Filipa Peixoto; Simone Morais
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-13 at 08:23:52 | Privacy Policy | Personal Data Protection Policy | Whistleblowing