Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Prognostic value of flow-status in severe aortic stenosis patients undergoing percutaneous intervention
Publication

Publications

Prognostic value of flow-status in severe aortic stenosis patients undergoing percutaneous intervention

Title
Prognostic value of flow-status in severe aortic stenosis patients undergoing percutaneous intervention
Type
Article in International Scientific Journal
Year
2024
Authors
Santos Ferreira, D
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Fernandes, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Diaz, SO
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Guerreiro, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Saraiva, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Barros, AS
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Leite-Moreira AF
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Pereira, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sampaio, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ribeiro, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Braga, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fontes-Carvalho R
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 40
Pages: 341-350
ISSN: 1569-5794
Publisher: Springer Nature
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00Z-DGN
Abstract (EN): Purpose Low-flow status is a mortality predictor in severe aortic stenosis (SAS) patients, including after transcatheter aortic valve implantation (TAVI) treatment. However, the best parameter to assess flow is unknown. Recent studies suggest that transaortic flow rate (FR) is superior to currently used stroke volume index (SVi) in defining low-flow states. Therefore, we aimed to evaluate the prognostic value of FR and SVi in patients undergoing TAVI.Methods A single-centre retrospective analysis of all consecutive patients treated with TAVI for SAS between 2011 and 2019 was conducted. Low-FR was defined as < 200 mL/s and low-SVi as < 35 mL/m2. Primary endpoint was all-cause five-year mortality, analyzed using Kaplan-Meier curves and Cox regression models. Secondary endpoint was variation of NYHA functional class six months after procedure. Patients were further stratified according to ejection fraction (EF < 50%).Results Of 489 cases, 59.5% were low-FR, and 43.1% low-SVi. Low-flow patients had superior surgical risk, worse renal function, and had a higher prevalence of coronary artery disease. Low-FR was associated with mortality (hazard ratio 1.36, p = 0.041), but not after adjustment to EuroSCORE II. Normal-SVi was not associated with survival, despite a significative p-trend for its continuous value. No associations were found for flow-status and NYHA recovery. When stratifying according to preserved and reduced EF, both FR and SVi did not predict all-cause mortality.Conclusion In patients with SAS undergoing TAVI, a low-FR state was associated with higher mortality, as well as SVi, but not at a 35 mL/m2 cut off.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

MSCT evaluation of patients with prior coronary bypass surgery: What we have and what we lack (2009)
Another Publication in an International Scientific Journal
Bettencourt, N; Chiribiri, A; Nagel, E
Giant right coronary aneurysm: a coronary CT angiography exhibited severe aneurysmatic dilation of the right coronary artery (2020)
Another Publication in an International Scientific Journal
von Hafe, P; Dias, G; Cardoso, F; Oliveira, M; Ladeiras-Lopes R; Leite, S
A challenging case of prosthetic mitral valve dysfunction: the value of multimodality imaging (2023)
Another Publication in an International Scientific Journal
Duarte, F; Teixeira, R; Ferreira, W; Pereira, E; Fontes-Carvalho R
Subclinical ventricular dysfunction in rheumatoid arthritis (2020)
Article in International Scientific Journal
Rodrigues, P; Ferreira, B; Fonseca, T; Costa, RQ; Cabral, S; Pinto, JL; Saraiva, F; Marinho, A; Huttin, O; Girerd, N; Bozec, E; Carvalho, HC; Ferreira, JP
Staging cardiac damage in patients with aortic regurgitation (2022)
Article in International Scientific Journal
Silva, G; Queiros, P; Silva, M; Saraiva, F; Barros, A; Ribeiro, J; Fontes-Carvalho R; Sampaio, F

See all (15)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-25 at 13:08:23 | Privacy Policy | Personal Data Protection Policy | Whistleblowing