Fast neutron dose response of a commercial polycarbonate

Title
Fast neutron dose response of a commercial polycarbonate
Type
Article in International Conference Proceedings Book
Year
2007
Authors
Souto, EB
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Campos, LL
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Other information
Authenticus ID: P-00Y-1DP
Abstract (EN): A commercial polycarbonate produced in Brazil is being studied to be used as neutron detector material using Solid State Nuclear Track Detection (SSNTD) method replacing the well-known detector materials Makrofol and CR-39. This technique is based on the damage (tracks) registration of charged particles produced by the interaction of neutrons with carbon and oxygen atoms of some dielectric materials. The IPEN dosimeter prototype is composed by 30 × 10 × 1.5 mm3 polycarbonate piece inserted between two Polymethyl Methacralate (PMMA) plates 2 mm thick. The prototypes were irradiated placed on an ISO slab phantom using an isotropic 241AmBe source at LN/LNMRI (Neutrons Laboratory of the National Laboratory of Ionizing Radiation Metrology). To study the dose response groups of five prototypes were irradiated with Hp(10) from 0.5 to 20 mSv with normal incidence and to investigate the angular incidence effect with Hp(10) = 5 mSv with incidence angles of 15°, 45°, 60°, 75°, 85° and 90°. The detectors were revealed by chemical etching with the solution PEW-40 during 3 h. The track density of the detector surface was determined by the average of track counting of five fields (20 × 0.1 mm2). The track response to equivalent dose Hp(10) showed a good agreement with linear fit in the studied interval. The track density strongly decreases for incidence angles higher than 45°. © 2007 Elsevier B.V. All rights reserved.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 3
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Development of a Brazilian gamma-neutron dosimeter (2008)
Article in International Conference Proceedings Book
Souto, EB; Campos, LL
BRAZILIAN GAMMA-NEUTRON DOSEMETER: RESPONSE TO <SUP>241</SUP>AmBe AND <SUP>252</SUP>Cf NEUTRON SOURCES (2011)
Article in International Conference Proceedings Book
Souto, EB; Campos, LL
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-06 at 05:29:21 | Privacy Policy | Personal Data Protection Policy | Whistleblowing