Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Solid contact PVC membrane electrodes based on neutral or charged carriers for the selective reading of anionic sulfamethoxazole and their application to the analysis of aquaculture water
Publication

Publications

Solid contact PVC membrane electrodes based on neutral or charged carriers for the selective reading of anionic sulfamethoxazole and their application to the analysis of aquaculture water

Title
Solid contact PVC membrane electrodes based on neutral or charged carriers for the selective reading of anionic sulfamethoxazole and their application to the analysis of aquaculture water
Type
Article in International Scientific Journal
Year
2012
Authors
Almeida, SAA
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Heitor, AM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sa, LC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Barbosa, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
da Conceicao, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Montenegro, MCBSM
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Sales, MGF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Journal
Vol. 92 No. 2
Pages: 479-495
ISSN: 0306-7319
Publisher: Taylor & Francis
Other information
Authenticus ID: P-002-GTN
Abstract (EN): Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 x 10(-5) to 1.0 x 10(-2) mol/L (10.0 to 2500 mu g/mL), and the limit of detection was 1.2 x 10(-5) mol/L (3.0 mg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 17
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Fluoroquinolones and sulfonamides: features of their determination in water. A review (2016)
Another Publication in an International Scientific Journal
Peixoto, PS; Toth, IV; Marcela A Segundo; Lima, JLFC
Tubular potentiometric detector used to determine As(V) in sediment extracts by flow injection (2006)
Article in International Scientific Journal
M. Beatriz Quinaz ; José L. F. C. Lima ; Enrique Barrado ; José A. Rodrguez
SPE sample pre-treatment using a mixed-mode sorbent of reverse-phase and ionic exchange for determination of ALMWOAs in waters (2014)
Article in International Scientific Journal
Rocha, ACS; Marisa M R Almeida; Clara C P Basto; M. Teresa S. D. Vasconcelos
Simultaneous analysis of 23 priority volatile compounds in water by solid-phase microextraction-gas chromatography-mass spectrometry and estimation of the method's uncertainty (2008)
Article in International Scientific Journal
Ana Dias Guimarães; José João Carvalho ; Maria de Fátima Alpendurada; Carlos Gonçalves

See all (33)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-14 at 22:34:39 | Privacy Policy | Personal Data Protection Policy | Whistleblowing