Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Optical biosensor for the detection of low concentrations of hydrogen peroxide in milk samples
Publication

Publications

Optical biosensor for the detection of low concentrations of hydrogen peroxide in milk samples

Title
Optical biosensor for the detection of low concentrations of hydrogen peroxide in milk samples
Type
Article in International Conference Proceedings Book
Year
2022
Authors
Vasconcelos, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Matias, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Mendes, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Arahjo, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Dias, B
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Jorge, PAS
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Saraivaa, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Conference on Optical Sensing and Detection VII Part of SPIE Photonics Europe Conference
ELECTR NETWORK, APR 03-MAY 15, 2022
Other information
Authenticus ID: P-00W-T06
Abstract (EN): A strategy for the detection of H2O2 as a milk adulterant using a single shot membrane sensor, is presented. Direct quantitative evaluation of H2O2 in raw, skimmed, semi-skimmed and whole milk was carried out based on a chemiluminescence reaction with luminol. For H2O2 water solutions a linear response was attained from 0.0001% to 0.007 %w/w, with a limit of detection of 3x10(-5) %w/w. A coefficient of determination, R-2, greater than 0.97 was achieved, with a relative standard deviation (RSD) not exceeding 10%. In the analyzed milk samples, the lowest H2O2 concentration detected was 0.001% w/w for raw and for skim milk and 0.002%w/w for, semi-skimmed and whole milk. The presented method is original, sensitive, rapid, and cost-effective. Due to the achieved sensitivity the method has great potential to be used for H2O2 detection in diverse areas, such as environmental monitoring and food quality.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-07 at 01:41:03 | Privacy Policy | Personal Data Protection Policy | Whistleblowing