Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Electrocardiogram lead conversion from single-lead blindly-segmented signals
Publication

Publications

Electrocardiogram lead conversion from single-lead blindly-segmented signals

Title
Electrocardiogram lead conversion from single-lead blindly-segmented signals
Type
Article in International Scientific Journal
Year
2022
Authors
Beco, SC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pinto, JR
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Jaime S Cardoso
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 22
Final page: 314
ISSN: 1472-6947
Publisher: Springer Nature
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Other information
Authenticus ID: P-00X-HZ4
Abstract (EN): Background The standard configuration's set of twelve electrocardiogram (ECG) leads is optimal for the medical diagnosis of diverse cardiac conditions. However, it requires ten electrodes on the patient's limbs and chest, which is uncomfortable and cumbersome. Interlead conversion methods can reconstruct missing leads and enable more comfortable acquisitions, including in wearable devices, while still allowing for adequate diagnoses. Currently, methodologies for interlead ECG conversion either require multiple reference (input) leads and/or require input signals to be temporally aligned considering the ECG landmarks. Methods Unlike the methods in the literature, this paper studies the possibility of converting ECG signals into all twelve standard configuration leads using signal segments from only one reference lead, without temporal alignment (blindly-segmented). The proposed methodology is based on a deep learning encoder-decoder U-Net architecture, which is compared with adaptations based on convolutional autoencoders and label refinement networks. Moreover, the method is explored for conversion with one single shared encoder or multiple individual encoders for each lead. Results Despite the more challenging settings, the proposed methodology was able to attain state-of-the-art level performance in multiple target leads, and both lead I and lead II seem especially suitable to convert certain sets of leads. In cross-database tests, the methodology offered promising results despite acquisition setup differences. Furthermore, results show that the presence of medical conditions does not have a considerable effect on the method's performance. Conclusions This study shows the feasibility of converting ECG signals using single-lead blindly-segmented inputs. Although the results are promising, further efforts should be devoted towards the improvement of the methodologies, especially the robustness to diverse acquisition setups, in order to be applicable to cardiac health monitoring in wearable devices and less obtrusive clinical scenarios.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 15
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

How to promote adverse drug reaction reports using information systems - a systematic review and meta-analysis (2016)
Another Publication in an International Scientific Journal
Ribeiro Vaz, I; Silva, AM; Cristina Costa Santos; Ricardo Cruz Correia
Using autoencoders as a weight initialization method on deep neural networks for disease detection (2020)
Article in International Scientific Journal
Ferreira, MF; Rui Camacho; Luis F Teixeira
Use of multidimensional item response theory methods for dementia prevalence prediction: an example using the Health and Retirement Survey and the Aging, Demographics, and Memory Study (2021)
Article in International Scientific Journal
Nichols E.; Abd-Allah F.; Abdoli A.; Abualhasan A.; Abu-Gharbieh E.; Afshin A.; Akinyemi R.O.; Alanezi F.M.; Alipour V.; Almasi-Hashiani A.; Arabloo J.; Ashraf-Ganjouei A.; Ayano G.; Ayuso-Mateos J.L.; Baig A.A.; Banach M.; Barboza M.A.; Barker-Collo S.L.; Baune B.T.; Bhagavathula A.S....(mais 80 authors)
The effect of a test ordering software intervention on the prescription of unnecessary laboratory tests - a randomized controlled trial (2017)
Article in International Scientific Journal
Carlos Martins; teixeira, a; Azevedo L; Luísa Sá; Paulo Santos; do Couto, MLGD; Costa-Pereira A; Alberto Hespanhol; Cristina Costa Santos
Reviewing the integration of patient data: how systems are evolving in practice to meet patient needs (2007)
Article in International Scientific Journal
Cruz Correia, RJ; Vieira Marques, PM; Ferreira, AM; Almeida, FC; Wyatt, JC; Costa Pereira, AM

See all (12)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-19 at 02:09:48 | Privacy Policy | Personal Data Protection Policy | Whistleblowing