Evaluation of Vectra® XT 3D Surface Imaging Technology in Measuring Breast Symmetry and Breast Volume

Title
Evaluation of Vectra® XT 3D Surface Imaging Technology in Measuring Breast Symmetry and Breast Volume
Type
Article in International Scientific Journal
Year
2023
Authors
Pham, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Alzul, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Elder, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
French, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Jaime S Cardoso
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Kaviani, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Meybodi, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 47
Pages: 1-7
ISSN: 0364-216X
Publisher: Springer Nature
Other information
Authenticus ID: P-00X-8NQ
Abstract (EN): Background Breast symmetry is an essential component of breast cosmesis. The Harvard Cosmesis scale is the most widely adopted method of breast symmetry assessment. However, this scale lacks reproducibility and reliability, limiting its application in clinical practice. The VECTRA (R) XT 3D (VECTRA (R)) is a novel breast surface imaging system that, when combined with breast contour measuring software (Mirror (R)), aims to produce a more accurate and reproducible measurement of breast contour to aid operative planning in breast surgery. Objectives This study aims to compare the reliability and reproducibility of subjective (Harvard Cosmesis scale) with objective (VECTRA (R)) symmetry assessment on the same cohort of patients. Methods Patients at a tertiary institution had 2D and 3D photographs of their breasts. Seven assessors scored the 2D photographs using the Harvard Cosmesis scale. Two independent assessors used Mirror (R) software to objectively calculate breast symmetry by analysing 3D images of the breasts. Results Intra-observer agreement ranged from none to moderate (kappa - 0.005-0.7) amongst the assessors using the Harvard Cosmesis scale. Inter-observer agreement was weak (kappa 0.078-0.454) amongst Harvard scores compared to VECTRA (R) measurements. Kappa values ranged 0.537-0.674 for intra-observer agreement (p < 0.001) with Root Mean Square (RMS) scores. RMS had a moderate correlation with the Harvard Cosmesis scale (r(s) = 0.613). Furthermore, absolute volume difference between breasts had poor correlation with RMS (R-2 = 0.133). Conclusion VECTRA (R) and Mirror (R) software have potential in clinical practice as objectifying breast symmetry, but in the current form, it is not an ideal test.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 7
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Use of Doppler in Breast Reduction with Superomedial or Superolateral Pedicles (2010)
Another Publication in an International Scientific Journal
Horta, R; Silva, P; Filipe, R; Costa, J; Bartosh, I; Amarante J; Silva, A
Herpes Zoster infection after trunk liposuction (2022)
Another Publication in an International Scientific Journal
Horta, R; Frias, F; Carvalho, F
Tuberous breast: A surgical challenge (2002)
Article in International Scientific Journal
Choupina, M; Malheiro, E; Pinho, C; Costa-Ferreira A; Pinto, A; Cardoso, A; Reis, J; Amarante J
The tuberous breast – a surgical challenge. (2002)
Article in International Scientific Journal
Choupina M; Malheiro E; Pinho C; Costa-Ferreira A; Pinto A; Cardoso A; Reis J; Amarante J
The "PIP Problem": Clinical and Histologic Characteristics (2013)
Article in International Scientific Journal
Correia Sa, I; Rodrigues Pereira, P; Marisa Marques

See all (13)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-21 at 21:21:42 | Privacy Policy | Personal Data Protection Policy | Whistleblowing