Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Evolutionary Algorithm EPSO Helping Doubly-Fed Induction Generators in Ride-Through-Fault
Publication

Publications

Evolutionary Algorithm EPSO Helping Doubly-Fed Induction Generators in Ride-Through-Fault

Title
Evolutionary Algorithm EPSO Helping Doubly-Fed Induction Generators in Ride-Through-Fault
Type
Article in International Conference Proceedings Book
Year
2009
Authors
José Alberto Barros
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS Without ORCID
Vladimiro Miranda
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
Pages: 2032-2039
Bucharest PowerTech Conference
Bucharest, ROMANIA, JUN 28-JUL 02, 2009
Indexing
Scientific classification
FOS: Engineering and technology > Electrical engineering, Electronic engineering, Information engineering
CORDIS: Technological sciences > Engineering > Electrical engineering
Other information
Authenticus ID: P-003-SRD
Abstract (EN): A tuning process of the PI (Proportional-Integral) controller gains of a doubly-fed induction generator's (DFIG) rotor side converter is described in this work. The purpose is to tune PI controllers to help the DFIG to survive to network faults, avoiding being tripped-off by under-voltage relays. The ride-through-fault capability of DFIGs improves system reliability and allows them to participate in the control and stabilization of a power system following system disturbances. The robust tuning of the DFIG rotor side converter's PI controllers may avoid undesired disconnections from the grid by, for instance, preventing over-currents in its variable frequency AC/DC/AC converter. This work presents an Evolutionary Particle Swarm Optimization-based (EPSO) approach to this tuning, with the aim of helping to limit the line-to-line voltage dip at the DFIG's terminals after a short-circuit, in order to avoid its tripping-off. The EPSO-based algorithm developed is validated at a typical Portuguese 15 kV Distribution Network with the integration of a DFIG, using the transient electromagnetic software package PSCAD/EMTDC (TM).
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-14 at 08:13:42 | Privacy Policy | Personal Data Protection Policy | Whistleblowing