Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Blood Flow of Bubbles Moving in Microchannels with Bifurcations
Publication

Publications

Blood Flow of Bubbles Moving in Microchannels with Bifurcations

Title
Blood Flow of Bubbles Moving in Microchannels with Bifurcations
Type
Chapter or Part of a Book
Year
2019
Authors
Bento, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lopes, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Maia, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pereira, AI
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernandes, CS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Miranda, JM
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Lima, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Indexing
Other information
Authenticus ID: P-00R-58M
Abstract (EN): The gas embolism is a well-known phenomenon. Previous studies have been performed to understand the formation, the behavior and the influence of air bubbles in microcirculation. This study aims to investigate the flow of bubbles in a microchannel network with bifurcations. For that purpose, a microchannel network was fabricated by soft lithography. The working fluids used were composed by sheep red blood cells (RBCs) suspended in dextran 40 and two different hematocrits were studied, 5% and 10%. The in vitro blood flow was analyzed for a flow rate of 10 µl/min, by using an inverted microscope and a high-speed camera. It was possible to visualize the formation of the bubbles and their behavior along the network. The results show that the passage of air bubbles influences the cells local concentration, since a higher concentration of cells was seen upstream to the bubble and lower concentrations downstream to the bubble. © Springer Nature Switzerland AG 2019.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2024 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-08-17 at 07:29:51 | Acceptable Use Policy | Data Protection Policy | Complaint Portal