Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Cardiovascular magnetic resonance myocardial feature tracking for quantitative viability assessment in ischemic cardiomyopathy
Publication

Publications

Cardiovascular magnetic resonance myocardial feature tracking for quantitative viability assessment in ischemic cardiomyopathy

Title
Cardiovascular magnetic resonance myocardial feature tracking for quantitative viability assessment in ischemic cardiomyopathy
Type
Article in International Scientific Journal
Year
2013
Authors
Schuster, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Paul, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bettencourt, N
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Morton, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Chiribiri, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ishida, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Hussain, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Jogiya, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Kutty, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bigalke, B
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Perera, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Nagel, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 166
Pages: 413-420
ISSN: 0167-5273
Publisher: Elsevier
Other information
Authenticus ID: P-004-ZZJ
Abstract (EN): Background: Low dose dobutamine stress magnetic resonance imaging is valuable to assess viability in patients with ischemic cardiomyopathy. Analysis is usually qualitative with considerable operator dependency. The aim of the current study was to investigate the feasibility of cine images derived quantitative cardiac magnetic resonance (CMR) myocardial feature tracking (FT) strain parameters to assess viability in patients with ischemic cardiomyopathy. Methods: 15 consecutive patients with ischemic cardiomyopathy referred for viability assessment were studied at 3 T at rest and during low dose dobutamine stress (5 and 10 mu g/kg/min of dobutamine). Subendocardial and subepicardial circumferential (Eccendo and Eccepi) and radial (Err) strains were assessed using steady state free precession (SSFP) cine images orientated in 3 short axis slices covering 16 myocardial segments. Results: Dysfunctional segments without scar (n=75) improved in all three strain parameters: Ecc(endo) (Rest: -10.5 +/- 6.9; 5 mu g: -12.1 +/- 6.9; 10 mu g: -14.1 +/- 9.2; p<0.05), Ecc(epi) (Rest: -7 +/- 4.8; 5 mu g: -8.2 +/- 5.5; 10 mu g: -9.1 +/- 5.9; p<0.05) and Err (Rest: 11.7 +/- 8.3; 5 mu g: 16 +/- 10.9; 10 mu g: 16.5 +/- 12.8; p<0.05). There was no response to dobutamine in dysfunctional segments with scar transmurality above 75% (n=6): Ecc(endo) (Rest: -4.7 +/- 3.0; 5 mu g: -2.9 +/- 2.5; 10 mu g: -6.6 +/- 3.3; p=ns), Ecc(epi) (Rest: -2.9 +/- 2.9; 5 mu g: -5.4 +/- 3.9; 10 mu g: -4.5 +/- 4.2; p=ns) and Err (Rest: 9.5 +/- 5; 5 mu g: 5.4 +/- 6.2; 10 mu g: 4.9 +/- 3.3; p=ns). Circumferential strain (Ecc(endo), Ecc(epi)) improved in all segments up to a transmurality of 75% (n= 60; p<0.05). Err improved in segments <50% transmurality (n=45; p<0.05) and remained unchanged above 50% transmurality (n=21; p=ns). Conclusions: CMR-FT is a novel technique, which detects quantitative wall motion derived from SSFP cine imaging at rest and with low dose dobutamine stress. CMR-FT holds promise of quantitative assessment of viability in patients with ischemic cardiomyopathy.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Wet BNP, fluid and hemodynamic status at discharge in acute heart failure - Reply (2010)
Another Publication in an International Scientific Journal
Pimenta J; Paulo, C; Mascarenhas, J; Gomes, A; Azevedo A; Rocha Goncalves, F; Bettencourt P
Troponin I elevation after pericardiocentesis for cardiac tamponade: a role for myocardial strain? (2001)
Another Publication in an International Scientific Journal
José Pedro Nunes; Magalhaes, D; Dias, P; Faria, DB
Towards the standardization of stem cell therapy studies for ischemic heart diseases: Bridging the gap between animal models and the clinical setting (2017)
Another Publication in an International Scientific Journal
Trindade, F; Leite-Moreira AF; Ferreira Martins, J; Ferreira, R; Falcao Pires, I; Vitorino, R
Time-dependence of cardiac biomarker levels in newborns with congenital heart defects: Umbilical cord versus peripheral newborn blood (2016)
Another Publication in an International Scientific Journal
Neves AL; Cabral, M; Leite-Moreira AF; Monterroso, J; ramalho, c; Guimarães H; Barros H; guimaraes, jt; Henriques Coelho, T; Areias JC
The tight tie of MAG versus SAG in CABG (2021)
Another Publication in an International Scientific Journal
Saraiva, FA; Cerqueira, RJ; Savarese, G; Leite-Moreira AF

See all (84)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-21 at 11:10:55 | Privacy Policy | Personal Data Protection Policy | Whistleblowing