Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Long-term outcome of adjustable transobturator male system for stress urinary incontinence in the Iberian multicentre study
Publication

Publications

Long-term outcome of adjustable transobturator male system for stress urinary incontinence in the Iberian multicentre study

Title
Long-term outcome of adjustable transobturator male system for stress urinary incontinence in the Iberian multicentre study
Type
Article in International Scientific Journal
Year
2020
Authors
Angulo, JC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Virseda Chamorro, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Arance, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ruiz, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ojea, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Carballo, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rodriguez, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pereira, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teyrouz, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rebassa, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Escribano, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teba, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Celada, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Madurga, B
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Martins, FE
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Mendes, PA
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Francisco Cruz
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 39
Pages: 1737-1745
ISSN: 0733-2467
Publisher: Wiley-Blackwell
Other information
Authenticus ID: P-00S-9YV
Resumo (PT):
Abstract (EN): Aim The aim of this study is to evaluate long-term durability and effectiveness of the adjustable transobturator male system (ATOMS). Materials and Methods The retrospective multicenter Iberian ATOMS study (n = 215) was updated to evaluate long-term continence status, complications, explants, and secondary treatments. Mean follow-up from surgery to March 2020 was 60.6 +/- 18.4 months (range, 39-91). Eleven patients deceased of an unrelated causes. Kaplan-Meier curves were performed to evaluate device durability and incontinence free of recurrence interval. The multivariate analysis defined the population at risk of device explant. Results A total of 155 patients were dry at the last follow-up visit (72.1%); 99 (46%) used no pads and 56 (26%) used a security pad/day with urine loss less than 10 mL; 96% of dry patients after adjustment remained free of incontinence 1 year later, 93.6% 2 years later, 91.1% 3 years later, 89.2% 5 years later, and 86.7% 8 years later. Complications during follow-up occurred in 43 of 215 (20%). In total, 25 (11.6%) devices were explanted and causes were inefficacy 11 (44%), inefficacy and pain 3 (12%), port erosion 10 (40%), and wound infection 1 (4%). The secondary implant was performed in 11 (5.1%) cases, 6 artificial urinary sphincter and 5 repeated ATOMS. Time to explant was associated to complications (P < .0001), baseline stress urinary incontinence (SUI) severity (P = .01), and former irradiation (P = .03). Multivariate analysis revealed complications (hazard ratio [HR] = 8.71; 3.83-19.82), baseline SUI severity (>5 compared to 1-2 pads/day; HR = 14.9; 1.87-125), and irradiation before ATOMS (HR = 2.26; 1.02-5.18) predicted earlier ATOMS explant. Three cases received radiation after implant without complication. Conclusions ATOMS device is efficacious and safe in the long term. Determinants for device explant include complications, baseline severity of incontinence, and previous irradiation. Currently, the durability of the device after 5 years is reassuring.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 9
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The urinary and prostatic microbiome in non-neurogenic male LUTS/BPH: A systematic review (2024)
Another Publication in an International Scientific Journal
Pina-Vaz, T; Silva, AC; Silva, C; Miranda, I; Francisco Cruz; Silva, JA
Neurotrophins in Bladder Function: What Do We Know and Where Do We Go From Here? (2014)
Another Publication in an International Scientific Journal
Cruz C.D.
Is the Urothelium Intelligent? (2010)
Another Publication in an International Scientific Journal
Birder, LA; Kanai, AJ; Francisco Cruz; Moore, K; Fry, CH
Is it Possible to Regenerate the Underactive Detrusor? Part 2 Electrical Stimulation Therapies, Treatment of Bladder Outlet Obstruction, Constipation, and Pelvic Floor Disorders ICI-RS 2024 (2024)
Another Publication in an International Scientific Journal
Sinha, S; Gajewski, JB; Tarcan, T; Van Huele, A; Francisco Cruz; Martinez, EM; Przydacz, M; Kheir, GB; Lombardo, R; Wein, A; Abrams, P

See all (26)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2025-07-04 at 14:53:25 | Acceptable Use Policy | Data Protection Policy | Complaint Portal