Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Evaluation of Adherence to Ambulatory Liquid Oxygen Treatment: Are Commercialized Dual-Pressure Transducers Helpful?
Publication

Publications

Evaluation of Adherence to Ambulatory Liquid Oxygen Treatment: Are Commercialized Dual-Pressure Transducers Helpful?

Title
Evaluation of Adherence to Ambulatory Liquid Oxygen Treatment: Are Commercialized Dual-Pressure Transducers Helpful?
Type
Article in International Scientific Journal
Year
2014
Authors
van Zeller, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Eusebio, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Winck, JC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: Respiratory CareImported from Authenticus Search for Journal Publications
Vol. 59
Pages: 1376-1380
ISSN: 0020-1324
Other information
Authenticus ID: P-00A-73N
Abstract (EN): BACKGROUND: Treatment adherence is widely recognized as a critical problem in long-term oxygen therapy, particularly in ambulatory liquid oxygen (LOX) systems. Adherence-monitoring strategies may be helpful in managing patients. We evaluated subjects' adherence to LOX using Vision Ox and compared these results with the subjects' own adherence diaries and self-reported perceptions of use. METHODS: Patients using LOX were recruited for a clinical interview; the number of days/week and the mean time of use according to subjects' perceptions were recorded. A 14-day diary was provided for every subject while Vision Ox was attached to the LOX. Vision Ox is a small device that uses pressure transducers to detect oxygen flow and the subject's breathing frequency. Information is stored and downloaded using dedicated software. RESULTS: Nineteen subjects were included (57.9% male with a median age of 63 years). When asked about the perception of LOX use, subjects self-reported using the device for a median of 100.0% of days (78.9% reported to have used it every day) for a median time of 180 min/day. According to data from Vision Ox and subjects' diaries during the 14-day evaluation period, the median use was 92.8% of days for 210 min/day. No difference was found between the diaries and Vision Ox data. Regarding subjects' perceptions of use, the declared use of LOX percent was significantly higher than reported in the diaries (P = .045) and VisionOx monitoring (P = .045) even though both underestimated the median use per day. CONCLUSIONS: Subjects overestimated adherence to LOX therapy (when measuring percent of days of use) compared to adherence diary and objective adherence monitoring. Because no significant difference was found comparing the diaries and VisionOx use, either may be helpful in clinical practice.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Adherence to ambulatory liquid oxygen using comercialized dual pressure transducers (2013)
Other Publications
van Zeller, M; Eusebio, E; Amorim, J; Fonseca, J; Winck, JC

Of the same journal

Mechanical Ventilation for the Treatment of Severe Excessive Dynamic Airway Collapse (2015)
Another Publication in an International Scientific Journal
Bastos, HN; Teixeira, N; Redondo, M; Goncaives, M; Sucena, M
The prognostic role of ventilatory inefficiency and exercise capacity in idiopathic pulmonary fibrosis (2016)
Article in International Scientific Journal
Baruch Vainshelboim; José Oliveira; Benjamin Daniel Fox; Mordechai Reuven Kramer
Population-Based Study on the Prevalence of Spirometric Obstructive Pattern in Porto, Portugal (2011)
Article in International Scientific Journal
Mascarenhas, J; Falcao, H; Lourenco, P; Paulo, C; Patacho, M; Bettencourt P; Azevedo A
Bleeding and Thrombotic Complications in COVID-19-Associated ARDS Requiring ECMO (2023)
Article in International Scientific Journal
Tavares, EP; Rebolo, JR; Pimentel, R; Roncon-Albuquerque R Jr
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-08 at 12:33:28 | Privacy Policy | Personal Data Protection Policy | Whistleblowing