Resumo (PT):
Abstract (EN):
Energy hubs are defined as energy systems that receive various energy carriers and convert or store them to serve different types of load demands. Stochastic scheduling methods can be used to optimally manage the energy hubs. However, in the stochastic approach, the main deficiency is that there exists the risk of experiencing the worst scenario, so a viable solution is needed to address this possibility. This paper addresses the two-stage operation scheduling of energy hubs based on the worst scenarios. A novel robust scenario-based approach is proposed and compared to the stochastic approach. A robustness parameter is defined to control the compromise between the expected operating costs and the model robustness. It can be seen that the model is robust against all the realization of worst scenarios.
Language:
English
Type (Professor's evaluation):
Scientific
No. of pages:
6