Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams
Publication

Publications

Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams

Title
Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams
Type
Article in International Scientific Journal
Year
2020
Authors
Czarnecki, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Zink, K
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pimpinella, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Borbinha, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teles, P
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Pinto, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 65
ISSN: 0031-9155
Other information
Authenticus ID: P-00T-9H4
Abstract (EN): Clinical dosimetry is typically performed using ion chambers calibrated in terms of absorbed dose to water. As primary measurement standards for this quantity for low and medium energy x-rays are available only since a few years, most dosimetry protocols for this photon energy range are still based on air kerma calibration. For that reason, data for beam quality correction factors k(Q,Q0), necessary for the application of dose to water based protocols, are scarce in literature. Currently the international IAEA TRS-398 Code of Practice is under revision and new k(Q,Q0) factors for a large number of ion chambers will be introduced in the update of this protocol. Several international groups provided the IAEA with experimental and Monte Carlo based data for this revision. Within the European Community the EURAMET 16NRM03 RTNORM project was initiated for that purpose. In the present study, Monte Carlo based results for the beam quality correction factors in medium energy x-ray beams for six ion chambers applying different Monte Carlo codes are presented. Additionally, the perturbation factor p(Q), necessary for the calculation of dose to water from an air kerma calibration coefficient, was determined. The beam quality correction factor k(Q,Q0) for the chambers varied in the investigated energy range by about 4%-5%, and for five out of six chambers the data could be fitted by a simple logarithmic function, if the half-value-layer was used as the beam quality specifier. Corresponding data using different Monte Carlo codes for the same ion chamber agreed within 0.5%. For the perturbation factor p(Q), the data did not obey a comparable simple relationship with the beam quality specifier. The variation of p(Q) for all ion chambers was in the range of 3%-4%. Compared to recently published data, our p(Q) data is around 1% larger, although the same Monte Carlo code has been used. Compared to the latest experimental data, there are even deviations in the range of 2%.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 14
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study (2013)
Article in International Scientific Journal
Figueira, C; Becker, F; Blunck, C; DiMaria, S; Baptista, M; Esteves, B; Paulo, G; Santos, J; Teles, P; Vaz, P
Determination of consensus k(Q) values for megavoltage photon beams for the update of IAEA TRS-398 (2020)
Article in International Scientific Journal
Andreo, P; Burns, DT; Kapsch, RP; McEwen, M; Vatnitsky, S; Andersen, CE; Ballester, F; Borbinha, J; Delaunay, F; Francescon, P; Hanlon, MD; Mirzakhanian, L; Muir, B; Ojala, J; Oliver, CP; Pimpinella, M; Pinto, M; de Prez, LA; Seuntjens, J; Sommier, L...(mais 4 authors)
Calculated beam quality correction factors for ionization chambers in MV photon beams (2020)
Article in International Scientific Journal
Tikkanen, J; Zink, K; Pimpinella, M; Teles, P; Borbinha, J; Ojala, J; Siiskonen, T; Goma, C; Pinto, M
A System for Digital Processing of Ophthalmic Images (1994)
Article in International Scientific Journal
Ana Maria Mendonça; Aurélio Campilho; José R. Nunes
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-14 at 09:05:55 | Privacy Policy | Personal Data Protection Policy | Whistleblowing