Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > PERFORMANCE ASSESSMENT AND UNCERTAINTY EVALUATION OF A PORTABLE NAI-BASED DETECTION SYSTEM USED FOR THYROID MONITORING
Publication

Publications

PERFORMANCE ASSESSMENT AND UNCERTAINTY EVALUATION OF A PORTABLE NAI-BASED DETECTION SYSTEM USED FOR THYROID MONITORING

Title
PERFORMANCE ASSESSMENT AND UNCERTAINTY EVALUATION OF A PORTABLE NAI-BASED DETECTION SYSTEM USED FOR THYROID MONITORING
Type
Article in International Scientific Journal
Year
2012
Authors
Bento, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Martins, B
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teles, P
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Neves, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Colarinha, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Alves, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teixeira, N
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vaz, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Zankl, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 151
Pages: 252-261
ISSN: 0144-8420
Other information
Authenticus ID: P-002-74N
Abstract (EN): This work aims at assessing the performance of a portable detection system, equipped with an NaI(TI) scintillation detector for in vivo thyroid monitoring, which was properly calibrated using an anthropomorphic neck phantom. The anthropomorphic physical phantoms commonly used for the efficiency calibration of in rho counters often present certain limitations regarding the geometry and the activity distribution. Therefore, the feasibility of these detection systems for in vivo monitoring should be assessed whenever possible. To accomplish this assessment, patients to whom Tc-99m and I-123 marked radiopharmaceuticals have been administered in the framework of nuclear medicine diagnostic procedures were monitored. As the biokinetic models of the administered radiopharmaceuticals are known, the time-dependent activity functions in the critical organs after administration are easily quantified. The measured activities in the thyroid using the NaI(TI) scintillation detector were compared with the estimated activities using the biokinetic models, in order to reach conclusion about the applicability of the portable scintillation counter for in vivo thyroid monitoring. The state-of-the-art Monte Carlo computer program PENELOPE and two voxel phantoms (male and female) were used to evaluate the overall uncertainties influencing the thyroid monitoring. A computational parametric study was performed to quantify the influence of several parameters in the activity quantification (neck-detector distance, thyroid shape, thyroid size and overlying tissue thickness), which allowed one to gain insight and to better understand the discrepancies between the calculated and measured activities.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

A REVIEW OF RADIATION PROTECTION REQUIREMENTS AND DOSE ESTIMATION FOR STAFF AND PATIENTS IN CT FLUOROSCOPY (2017)
Another Publication in an International Scientific Journal
Teles, P; Nikodemova, D; Bakhanova, E; Becker, F; Knezevic, Z; Pereira, MF; Sarmento, S
Study of nuclear medicine practices in Portugal from an internal dosimetry perspective (2012)
Article in International Scientific Journal
Bento, J; Teles, P; Neves, M; Santos, AI; Cardoso, G; Barreto, A; Alves, F; Guerreiro, C; Rodrigues, A; Santos, JAM; Capelo, C; Parafita, R; Martins, B
On the Placement of Apron Dosemeters and Dose Assessment in Interventional Cardiology Procedures: Preliminary Results (2022)
Article in International Scientific Journal
Ferrari, P; Becker, F; Campani, L; Jansen, J; Jovanovie, Z; Krstie, D; Mariotti, F; Teles, P; Venturi, G
Monte Carlo simulation of the movement and detection efficiency of a whole-body counting system using a BOMAB phantom (2012)
Article in International Scientific Journal
Bento, J; Barros, S; Teles, P; Neves, M; Goncalves, I; Corisco, J; Vaz, P
Human exposure to indoor radon: a survey in the region of Guarda, Portugal (2013)
Article in International Scientific Journal
Louro, A; Peralta, L; Soares, S; Pereira, A; Cunha, G; Belchior, A; Ferreira, L; Gil, OM; Louro, H; Pinto, P; Rodrigues, AS; Silva, MJ; Teles, P

See all (14)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-13 at 19:11:53 | Privacy Policy | Personal Data Protection Policy | Whistleblowing