Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Tissue composition and density impact on the clinical parameters for I-125 prostate implants dosimetry
Publication

Publications

Tissue composition and density impact on the clinical parameters for I-125 prostate implants dosimetry

Title
Tissue composition and density impact on the clinical parameters for I-125 prostate implants dosimetry
Type
Article in International Scientific Journal
Year
2014
Authors
Oliveira, SM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teixeira, NJ
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernandes, L
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teles, P
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Vieira, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vaz, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: Physica MedicaImported from Authenticus Search for Journal Publications
Vol. 30
Pages: 799-808
ISSN: 1120-1797
Other information
Authenticus ID: P-009-Z9Z
Abstract (EN): The MCNPX code was used to calculate the TG-43U1 recommended parameters in water and prostate tissue in order to quantify the dosimetric impact in 30 patients treated with I-125 prostate implants when replacing the TG-43U1 formalism parameters calculated in water by a prostate-like medium in the planning system (PS) and to evaluate the uncertainties associated with Monte Carlo (MC) calculations. The prostate density was obtained from the CT of 100 patients with prostate cancer. The deviations between our results for water and the TG-43U1 consensus dataset values were -2.6% for prostate V-100, -13.0% for V-150, and -5.8% for D-90: -2.0% for rectum V-100, and -5.1% for D-0.1; -5.0% for urethra D-10, and -5.1% for D-30. The same differences between our water and prostate results were all under 0.3%. Uncertainties estimations were up to 2.9% for the g(L)(r) function, 13.4% for the F(r,theta) function and 7.0% for Lambda, mainly due to seed geometry uncertainties. Uncertainties in extracting the TG-43U1 parameters in the MC simulations as well as in the literature comparison are of the same order of magnitude as the differences between dose distributions computed for water and prostate-like medium. The selection of the parameters for the PS should be done carefully, as it may considerably affect the dose distributions. The seeds internal geometry uncertainties are a major limiting factor in the MC parameters deduction. (C) 2014 Published by Elsevier Ltd on behalf of Associazione Italiana di Fisica Medica.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Effect of reconstruction processing methods and analysis in the quantification of brain spect studies with DaTSCANTM (2016)
Another Publication in an International Scientific Journal
Diogo Faria; Joana Vale; João Manuel R. S. Tavares; José Manuel Oliveira; Durval Costa
69. The European epidemiological study (EURALOC) on radiation-induced lens opacities among interventional cardiologists (2018)
Article in International Scientific Journal
Struelens, L; Covens, P; Benadjaoud, M; Auvinen, A; Gianicolo, E; Wegener, A; Domienik, J; Carinou, E; Dragusin, O; Teles, P; Widmark, A; Ciraj-Bjelac, O; Andreassi, MG; Padovani, R
4 MV photon beams dosimetry with Kodak X-Omat V films for external radiotherapy (2001)
Article in International Scientific Journal
Clemencio, EMC; Lopes, MC; Correia, CMBA
[OA074] Fano theory validation of the MCNP6.0 Monte Carlo code for medical applications (2018)
Article in International Scientific Journal
Teles, P; Maria, Sd; Pinto, M; Delaunay, F
Monte Carlo: a particle transport simulation code in Python (2021)
Article in International Scientific Journal
Campos, R; Teles, P

See all (13)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-10 at 10:19:23 | Privacy Policy | Personal Data Protection Policy | Whistleblowing