Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry
Publication

Publications

Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry

Title
Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry
Type
Article in International Scientific Journal
Year
2018
Authors
Van Keer, K
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Van Keer, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Breda, JB
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Nassiri, V
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
De Deyne, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Genbrugge, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pinto, LA
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Stalmans, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vandewalle, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: PLoS ONEImported from Authenticus Search for Journal Publications
Vol. 13 No. 1
ISSN: 1932-6203
Other information
Authenticus ID: P-00N-FZ5
Resumo (PT):
Abstract (EN): Background To investigate the correlation between cerebral (SO2-transcranial), retinal arterial (SaO(2-retinal)) and venous (SvO(2-retinal)) oxygen saturation as measured by near-infrared spectroscopy (NIRS) and retinal oximetry respectively. Methods Paired retinal and cerebral oxygen saturation measurements were performed in healthy volunteers. Arterial and venous retinal oxygen saturation and diameter were measured using a non-invasive spectrophotometric retinal oximeter. Cerebral oxygen saturation was measured using near-infrared spectroscopy. Correlations between SO2-transcranial and retinal oxygen saturation and diameter measurements were assessed using Pearson correlation coefficients. Lin's concordance correlation coefficient (CCC) and Bland-Altman analysis were performed to evaluate the agreement between SO2-transcranial as measured by NIRS and as estimated using a fixed arterial: venous ratio as 0.3 x SaO(2-retinal) + 0.7 x SvO(2-retinal). The individual relative weight of SaO(2-retinal) and SvO(2-retinal) to obtain the measured SO2-transcranial was calculated for all subjects. Results Twenty-one healthy individuals aged 26.4 +/- 2.2 years were analyzed. SO2-transcranial was positively correlated with both SaO(2-retinal) and SvO(2-retinal) (r = 0.44, p = 0.045 and r = 0.43, p = 0.049 respectively) and negatively correlated with retinal venous diameter (r = -0.51, p = 0.017). Estimated SO2-transcranial based on retinal oximetry showed a tolerance interval of (-13.70 to 14.72) and CCC of 0.46 (95% confidence interval: 0.05 to 0.73) with measured SO2-transcranial. The average relative weights of SaO(2-retinal) and SvO(2-retinal) to obtain SO2-transcranial were 0.31 +/- 0.11 and 0.69 +/- 0.11, respectively. Conclusion This is the first study to show the correlation between retinal and cerebral oxygen saturation, measured by NIRS and retinal oximetry. The average relative weight of arterial and venous retinal oxygen saturation to obtain the measured transcranial oxygen saturation as measured by NIRS, approximates the established arterial: venous ratio of 30:70 closely, but shows substantial inter-individual variation. These findings provide a proof of concept for the role of retinal oximetry in evaluating cerebral oxygenation.
Language: English
Type (Professor's evaluation): Dissemination
No. of pages: 14
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Reliability in long-term clinical studies of disease-modifying therapies for relapsing-remitting multiple sclerosis: A systematic review (2020)
Another Publication in an International Scientific Journal
Lucchetta, RC; Leonart, LP; Goncalves, MVM; Becker, J; Pontarolo, R; Fernandez Llimos, F; Wiens, A
Questionnaires measuring movement behaviours in adults and older adults: Content description and measurement properties. A systematic review (2022)
Another Publication in an International Scientific Journal
Rodrigues, B; Encantado, J; Carraca, E; Sousa Sa, E; Lopes, L; Cliff, D; Mendes, R; Silva, MN; Godinho, C; Santos, R
Mapping the characteristics of network meta-analyses on drug therapy: A systematic review (2018)
Another Publication in an International Scientific Journal
Tonin, FS; Steimbach, LM; Mendes, AM; Borba, HH; Pontarolo, R; Fernandez Llimos, F
Fecal microbiota transplantation in inflammatory bowel disease patients: A systematic review and meta-analysis (2020)
Another Publication in an International Scientific Journal
Caldeira, LD; Borba, HH; Tonin, FS; Wiens, A; Fernandez Llimos, F; Pontarolo, R
Establishing the criterion validity of self-report measures of adherence in hemodialysis through associations with clinical biomarkers: A systematic review and meta-analysis (2022)
Another Publication in an International Scientific Journal
Sousa, H; Ribeiro, O; Costa, E; Christensen, AJ; Figueiredo, D

See all (436)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-18 at 21:02:32 | Privacy Policy | Personal Data Protection Policy | Whistleblowing