Você está em: Start > Publications > View > Three-way calibration using PARAFAC and MCR-ALS with previous synchronization of second-order chromatographic data through a new functional alignment of pure vectors for the quantification in the presence of retention time shifts in peak position and shape
Publication

Publications

Three-way calibration using PARAFAC and MCR-ALS with previous synchronization of second-order chromatographic data through a new functional alignment of pure vectors for the quantification in the presence of retention time shifts in peak position and shape

Title
Three-way calibration using PARAFAC and MCR-ALS with previous synchronization of second-order chromatographic data through a new functional alignment of pure vectors for the quantification in the presence of retention time shifts in peak position and shape
Type
Article in International Scientific Journal
Year
2021
Authors
Mazivila, SJ
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lombardi, JM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pascoa, RNMJ
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bortolato, SA
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Leitao, JMM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Joaquim C G E Esteves da Silva
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Journal
Vol. 1146
Pages: 98-108
ISSN: 0003-2670
Publisher: Elsevier
Other information
Authenticus ID: P-00T-81Y
Abstract (EN): In the present contribution is shown the application of the recently developed functional alignment of pure vectors (FAPV) as a proper algorithm to align second-order chromatographic data with severe retention time shifts in peak position and shape. FAPV decomposed a three-way chromatographic data array in their three modes (sample, spectral and elution time vectors), using a basis function to pre-process the non-linear mode (elution time) and then it aligns the functionalized pure vectors and reshapes the transformed vectors into matrices, restoring the trilinearity of second-order chromatographic data. The well-aligned three-way chromatographic data array is then successfully decomposed by advanced chemometric models such as parallel factor analysis (PARAFAC) and multivariate curve resolution - alternating least-squares (MCR-ALS) with the trilinearity constraint. The performance of this innovative analytical strategy based on PARAFAC and MCR-ALS with previous synchronization of data through FAPV algorithm is properly evaluated using real second-order chromatographic data with multiple artifacts, i.e., shifts in peak position and shape for the simultaneous quantification of amoxicillin and potassium clavulanate in commercial medicinal drugs. The present contribution compares some analytical results achieved by: (1) the usual MCR-ALS as a bilinear model applied in augmented data matrix without previous synchronization and with interval correlation optimized shifting (ICOSHIFT) and FAPV and (2) trilinear models using PARAFAC with ICOSHIFT and FAPV and trilinearity constraint in MCR-ALS with FAPV. Available results suggest that these strongly shifted and warped elution time profiles cause for the loss of trilinearity, which can be adequately restored by FAPV algorithm. PARAFAC performed a successful trilinear decomposition of three-way chromatographic data array with law values of relative prediction error (REP) in the order of 1.34-1.42% in both analytes.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 11
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS (1986)
Another Publication in an International Scientific Journal
ALONSO, J; BARTROLI, J; Lima, JLFC; MACHADO, AASC
Papers presented at the 10th International Conference on Flow Analysis Porto, Portugal, 3-8 September 2006 - Foreword (2007)
Another Publication in an International Scientific Journal
Purnendu Dasgupta; Jose L F C Lima; Lucia Saraiva; Marcela Segundo
Optical probes for detection and quantification of neutrophils' oxidative burst. A review (2009)
Another Publication in an International Scientific Journal
Marisa Freitas; Jose L F C Lima; Eduarda Fernandes
Nanoparticle-based assays in automated flow systems: A review (2015)
Another Publication in an International Scientific Journal
Marieta L C Passos; Paula C A G Pinto; Joao L M Santos; Lucia L M F S Saraiva; Andre R T S Araujo

See all (221)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-10 at 09:37:30 | Privacy Policy | Personal Data Protection Policy | Whistleblowing