Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Optimisation of IGBT switching by adaptive gate voltage control
Publication

Publications

Optimisation of IGBT switching by adaptive gate voltage control

Title
Optimisation of IGBT switching by adaptive gate voltage control
Type
Article in International Conference Proceedings Book
Year
1995
Authors
Adriano Carvalho
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Martins, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Araujo, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 227-230
Proceedings of the 1995 IEEE 38th Midwest Symposium on Circuits and Systems. Part 1 (of 2)
Rio de Janeiro, Braz, 13 August 1995 through 16 August 1995
Indexing
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-007-6QG
Abstract (EN): The short circuit clearance in switching of PWM 3 phase inverters in a few industrial applications must be done in such a way that the maximum current and voltage ratings are not exceeded. The probability of frequent load short circuit, due to the load conditions, justifies the use of a special gate turn off scheme. As conventional RCD topologies should be avoided, in power inverters, due to additional stresses in the IGBT, owing to the interaction between the complementary snubber capacitors of an arm, this justifies the choice for a commutation aid and protection circuit based on a voltage limiter. Conventional drives, which have current commutation time optimised for the normal conditions of the converter, react fastly to the fault. This fast commutation diverts almost all the short circuit current to the limiter capacitor causing its overdimensioning, for the short circuit condition. If the short circuit current could be shared between the limiter and the power semiconductor the overvoltage may be reduced enabling the use of a capacitor with almost the same rating necessary for normal operation. This benefits the duties and working frequency. This paper presents the design and operation characteristics of a drive protection circuit ruling these characteristics.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-21 at 21:03:35 | Privacy Policy | Personal Data Protection Policy | Whistleblowing