Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Longitudinal evaluation of computerized cardiotocographic parameters throughout pregnancy in normal fetuses: a prospective cohort study
Publication

Publications

Longitudinal evaluation of computerized cardiotocographic parameters throughout pregnancy in normal fetuses: a prospective cohort study

Title
Longitudinal evaluation of computerized cardiotocographic parameters throughout pregnancy in normal fetuses: a prospective cohort study
Type
Article in International Scientific Journal
Year
2016
Authors
Amorim Costa, C
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Diogo Ayres de Campos
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Joao Bernardes
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 95
Pages: 1143-1152
ISSN: 0001-6349
Publisher: Wiley-Blackwell
Other information
Authenticus ID: P-00K-XJM
Abstract (EN): Introduction. The longitudinal cardiotocographic (CTG) changes throughout pregnancy in normal fetuses have never been fully described. We aimed at characterizing the evolution of CTG parameters in healthy fetuses, from 24 to 41 weeks of gestation. Material and methods. A prospective cohort study was conducted in singleton fetuses without structural abnormalities on second-trimester ultrasound. At least one CTG was performed in each of the following intervals: 24-26 weeks(+6d), 27-29 weeks(+6d), 30-32 weeks(+6d), 33-35 weeks(+6d), 36-38 weeks(+6d) and >= 39 weeks; tracings were analyzed by the OMNIVIEW-SISPORTO 3.6 system. Cases of preterm delivery, fetal death, birthweight under the 10th percentile, low five-minute Apgar, umbilical artery acidemia or neonatal intensive care unit admission were subsequently excluded. Results. A total of 1049 eligible tracings were obtained from 145 fetuses. There was a significant increase over time in average long-term variability (LTV), average short-term variability (STV), number of accelerations and uterine contractions. Conversely, fetal heart rate (FHR) baseline and number of decelerations decreased. A high inter-fetal variability was observed, but there was considerable intra-fetal consistency. Fetuses showing a marked decrease in FHR baseline and those with a marked increase in average LTV had a significantly lower birthweight. Cesarean section rate was significantly higher in cases with a decrease in average STV throughout gestation. Conclusions. This prospective longitudinal study shows an evolution in computerized CTG parameters during pregnancy, indicating the need to adapt interpretation criteria based on gestational age. The high inter-fetal variability and considerable intra-fetal consistency suggests the possible value of using each fetus as its own reference in serial assessments.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

The limits of agreement and the intraclass correlation coefficient may be inconsistent in the interpretation of agreement (vol 64, pg 264, 2011) (2011)
Other Publications
Cristina Costa Santos; Joao Bernardes; Diogo Ayres de Campos; Antonia Costa; Amorim Costa, C

Of the same journal

Maternal heart rate analysis during labor. Has the time come for computerized analysis? (2012)
Another Publication in an International Scientific Journal
Joao Bernardes; Diogo Ayres de Campos
Interobserver agreement according to STAN guidelines (2008)
Another Publication in an International Scientific Journal
Costa Santos C; Bernardes J
Electronic fetal monitoring: What's reassuring? (multiple letters) [1] (1999)
Another Publication in an International Scientific Journal
Joao Bernardes; Berkus, MD
Electronic fetal monitoring: what's reassuring? (1999)
Another Publication in an International Scientific Journal
Joao Bernardes

See all (20)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-22 at 11:53:45 | Privacy Policy | Personal Data Protection Policy | Whistleblowing