Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Buckling resistance of partially encased columns embedded on walls under fire from one side
Publication

Publications

Buckling resistance of partially encased columns embedded on walls under fire from one side

Title
Buckling resistance of partially encased columns embedded on walls under fire from one side
Type
Chapter or Part of a Book
Year
2020
Authors
Paulo A. G. Piloto
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Nathália Gonçales
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ronaldo Rigobello
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Mário Vaz
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Rui Miranda Guedes
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
João Santos Baptista
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Indexing
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00R-9A5
Resumo (PT):
Abstract (EN): Partially encased columns (PEC) have better fire resistance when compared to bare steel columns, due to the existence of concrete between the flanges. The aim of this study is to develop a new proposal for the calculation of the buckling strength of partially encased columns, embedded on walls, under fire conditions. This proposal is based on the current calculation method proposed in Annex G of EN 1994-1-2. This study uses the finite element method to calculate the average temperature of seven components. The average temperature is then used to find the buckling resistance of composite columns when submitted to fire from one side. This solution method is carried out using 30 different cross sections. All cross sections are exposed to the standard fire curve ISO834 from one side, assuming the specific fire rating of 30, 60, 90 and 120 min. © Springer Nature Switzerland AG 2020.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 17
Documents
We could not find any documents associated to the publication.