Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Quality assessment and feedback of Smart Device Microphone Spirometry executed by children
Publication

Publications

Quality assessment and feedback of Smart Device Microphone Spirometry executed by children

Title
Quality assessment and feedback of Smart Device Microphone Spirometry executed by children
Type
Article in International Conference Proceedings Book
Year
2019
Authors
Pinho, B
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Jacome, C
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Teixeira, JF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Amaral, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lopes, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Guedes, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pereira, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Goncalves, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
6th IEEE Portuguese Meeting on Bioengineering, ENBENG 2019
22 February 2019 through 23 February 2019
Other information
Authenticus ID: P-00Q-J2B
Abstract (EN): Smart device microphone spirometry, based on the audio recording of forced expiratory maneuver (FEM), can be a simple, ubiquitous and easy tool for patients to self-monitor their asthma. Automatic validity assessment is crucial to guarantee that the global effort of the FEM fulfil the admissible minimum or if the maneuver needs to be repeated. In this work an automatic method to classify the sounds from FEM with respect to global effort was developed and evaluated using data from 54 children (5-10 years). The method proposed was able to correctly classify the microphone spirometry with respect to admissible minimum of effort with an accuracy of 86% (specificity 87% and sensitivity 86%). This method can be used to provide immediate feedback of the correct execution of the maneuver, improving the clinical value and utility of this self-monitoring tool.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-19 at 03:51:02 | Privacy Policy | Personal Data Protection Policy | Whistleblowing