Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Dynamic security of islanded power systems with pumped storage power plants for high renewable integration - A study case
Publication

Publications

Dynamic security of islanded power systems with pumped storage power plants for high renewable integration - A study case

Title
Dynamic security of islanded power systems with pumped storage power plants for high renewable integration - A study case
Type
Article in International Scientific Journal
Year
2019
Authors
Maria Helena Vasconcelos
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Pedro Beires
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Carlos Leal Moreira
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
João Abel Peças Lopes
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
The Journal is awaiting validation by the Administrative Services.
Vol. 2019 No. 18
Pages: 4955-4960
Indexing
Other information
Authenticus ID: P-00Q-SG5
Abstract (EN): This work consists in assessing a real islanded power system from a dynamic security point of view, to support the planned installation, in the near future, of a hydro power plant with pumped storage, aiming to increase the integration of renewable energy. The analysed hydro power plant will include a Pelton turbine as it is a high-head hydro facility. Due to economic reasons, the adopted water pumping technology consists in fixed speed pumps coupled to induction motors with direct grid connection. It was possible to verify through detailed simulations of this power system's time domain behaviour that, even though the expected installation of this new power plant will bring additional frequency stability constraints, a robust technical solution may be found dealing with the new constraints without increasing the complexity of operation in this islanded power system. The conclusions obtained from this specific case are also valid for similar isolated power systems, namely when hydro pumping stations are being considered to increase time-variable renewable generation penetration.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-18 at 05:21:31 | Privacy Policy | Personal Data Protection Policy | Whistleblowing