Abstract (EN):
The simplified assessment of second-order effects is usually done in most codes of practice - EC2, EC3, ACI and AISC - by the amplification of first-order moments in a relation between the structural element's axial load and its critical buckling load. Another method for the consideration of such effects is proposed by CEB-FIP's Model Code 90, by the increment due to the presence of vertical load on the deformed structure load is estimated by rotation of the structure due to first-order loads by a direct proportion. This paper presents an extension of the Model Code 90 method to three-dimensional framed structures. After the basic theory is presented, numerical examples of the proposed method are compared with a more accurate nonlinear geometric analysis, testing the validity of the proposed equations and outlining its principal limitations. © Civil-Comp Press, 2009.
Language:
English
Type (Professor's evaluation):
Scientific
No. of pages:
20