Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Parametric model fitting-based approach for retinal blood vessel caliber estimation in eye fundus images
Publication

Publications

Parametric model fitting-based approach for retinal blood vessel caliber estimation in eye fundus images

Title
Parametric model fitting-based approach for retinal blood vessel caliber estimation in eye fundus images
Type
Article in International Scientific Journal
Year
2018
Authors
Teresa Araújo
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Ana Maria Mendonça
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Aurélio Campilho
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Journal
Title: PLoS ONEImported from Authenticus Search for Journal Publications
Vol. 13 No. 1
Pages: 1-27
ISSN: 1932-6203
Other information
Authenticus ID: P-00N-V6E
Abstract (EN): Background Changes in the retinal vessel caliber are associated with a variety of major diseases, namely diabetes, hypertension and atherosclerosis. The clinical assessment of these changes in fundus images is tiresome and prone to errors and thus automatic methods are desirable for objective and precise caliber measurement. However, the variability of blood vessel appearance, image quality and resolution make the development of these tools a non-trivial task. Metholodogy A method for the estimation of vessel caliber in eye fundus images via vessel cross-sectional intensity profile model fitting is herein proposed. First, the vessel centerlines are determined and individual segments are extracted and smoothed by spline approximation. Then, the corresponding cross-sectional intensity profiles are determined, post-processed and ultimately fitted by newly proposed parametric models. These models are based on Difference-of-Gaussians (DoG) curves modified through a multiplying line with varying inclination. With this, the proposed models can describe profile asymmetry, allowing a good adjustment to the most difficult profiles, namely those showing central light reflex. Finally, the parameters of the best-fit model are used to determine the vessel width using ensembles of bagged regression trees with random feature selection. Results and conclusions The performance of our approach is evaluated on the REVIEW public dataset by comparing the vessel cross-sectional profile fitting of the proposed modified DoG models with 7 and 8 parameters against a Hermite model with 6 parameters. Results on different goodness of fitness metrics indicate that our models are constantly better at fitting the vessel profiles. Furthermore, our width measurement algorithm achieves a precision close to the observers, outperforming state-of-the art methods, and retrieving the highest precision when evaluated using cross-validation. This high performance supports the robustness of the algorithm and validates its use in retinal vessel width measurement and possible integration in a system for retinal vasculature assessment.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 27
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

IDRiD: Diabetic Retinopathy - Segmentation and Grading Challenge (2020)
Article in International Scientific Journal
Prasanna Porwal; Samiksha Pachade; Manesh Kokare; Girish Deshmukh; Jaemin Son; Woong Bae; Lihong Liu; Jianzong Wang; Xinhui Liu; Liangxin Gao; TianBo Wu; Jing Xiao; Fengyan Wang; Baocai Yin; Yunzhi Wang; Gopichandh Danala; Linsheng He; Yoon Ho Choi; Yeong Chan Lee; Sang-Hyuk Jung...(mais 37 authors)
DR vertical bar GRADUATE: Uncertainty-aware deep learning-based diabetic retinopathy grading in eye fundus images (2020)
Article in International Scientific Journal
Teresa Araújo; Guilherme Aresta; Luís Mendonça; Susana Penas; Carolina Maia; Ângela Carneiro; Ana Maria Mendonça; Aurélio Campilho
Data Augmentation for Improving Proliferative Diabetic Retinopathy Detection in Eye Fundus Images (2020)
Article in International Scientific Journal
Teresa Araújo; Guilherme Aresta; Luís Mendonça; Susana Penas; Carolina Maia; Ângela Carneiro; Ana Maria Mendonça; Aurélio Campilho
UOLO - Automatic Object Detection and Segmentation in Biomedical Images (2018)
Article in International Conference Proceedings Book
Teresa Araújo; Guilherme Aresta; Adrian Galdran; Pedro Costa; Ana Maria Mendonça; Aurélio Campilho
Retinal Image Quality Assessment by Mean-Subtracted Contrast-Normalized Coefficients (2018)
Article in International Conference Proceedings Book
Adrian Galdran; Teresa Araújo; Ana Maria Mendonça; Aurélio Campilho

See all (9)

Of the same journal

Reliability in long-term clinical studies of disease-modifying therapies for relapsing-remitting multiple sclerosis: A systematic review (2020)
Another Publication in an International Scientific Journal
Lucchetta, RC; Leonart, LP; Goncalves, MVM; Becker, J; Pontarolo, R; Fernandez Llimos, F; Wiens, A
Questionnaires measuring movement behaviours in adults and older adults: Content description and measurement properties. A systematic review (2022)
Another Publication in an International Scientific Journal
Rodrigues, B; Encantado, J; Carraca, E; Sousa Sa, E; Lopes, L; Cliff, D; Mendes, R; Silva, MN; Godinho, C; Santos, R
Mapping the characteristics of network meta-analyses on drug therapy: A systematic review (2018)
Another Publication in an International Scientific Journal
Tonin, FS; Steimbach, LM; Mendes, AM; Borba, HH; Pontarolo, R; Fernandez Llimos, F
Fecal microbiota transplantation in inflammatory bowel disease patients: A systematic review and meta-analysis (2020)
Another Publication in an International Scientific Journal
Caldeira, LD; Borba, HH; Tonin, FS; Wiens, A; Fernandez Llimos, F; Pontarolo, R
Establishing the criterion validity of self-report measures of adherence in hemodialysis through associations with clinical biomarkers: A systematic review and meta-analysis (2022)
Another Publication in an International Scientific Journal
Sousa, H; Ribeiro, O; Costa, E; Christensen, AJ; Figueiredo, D

See all (436)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-12 at 18:14:38 | Privacy Policy | Personal Data Protection Policy | Whistleblowing