Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Spirometry-adjusted fraction of exhaled nitric oxide increases accuracy for assessment of asthma control in children
Publication

Publications

Spirometry-adjusted fraction of exhaled nitric oxide increases accuracy for assessment of asthma control in children

Title
Spirometry-adjusted fraction of exhaled nitric oxide increases accuracy for assessment of asthma control in children
Type
Article in International Scientific Journal
Year
2017
Authors
Martins, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Silva, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Severo, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rufo, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Paciencia, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Madureira, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Padrão, Patrícia
(Author)
FCNAUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Moreira, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Delgado, L
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernandes, EO
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Barros, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Malmberg, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Moreira, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 28
Pages: 754-762
ISSN: 0905-6157
Publisher: Wiley-Blackwell
Scientific classification
CORDIS: Health sciences
FOS: Medical and Health sciences
Other information
Authenticus ID: P-00N-BAB
Abstract (EN): Spirometry and exhaled nitric oxide are two important complimentary tools to identify and assess asthma control in children. We aimed to determine the ability of a new suggested spirometry-adjusted fraction of exhaled nitric oxide (NO) index in doing that. A random sample of 1602 schoolchildren were screened by a health questionnaire, skin prick tests, spirometry with bronchodilation and exhaled NO. A total of 662 children were included with median (IQR) exhaled NO 11(14) ppb. Receiver operating characteristic (ROC) curves using exhaled NO equations from Malmberg, Kovesi and Buchvald, and spirometry-adjusted fraction of exhaled NO values were applied to identify asthmatic children and uncontrolled asthma. Receiver operating characteristic (ROC) curves failed to identify asthmatic children (all AUC<0.700). Spirometry-adjusted fraction of exhaled NO/FEV1 (AUC=0.712; P=.010) and NO/FEF25%-75% (AUC=0.735 P=.004) had a fair and increased ability to identify uncontrolled disease compared with exhaled NO (AUC=0.707; P=.011) or the Malmberg equation (AUC=0.701; P=.014). Sensitivity and specificity identifying non-controlled asthma were 59% and 81%, respectively, for the cut-off value of 9.7ppb/L for exhaled NO/FEV1, and 40% and 100% for 15.7ppb/L/s for exhaled NO/FEF25%-75%. Exhaled NO did not allow to identify childhood asthma. Spirometry-adjusted fraction of exhaled NO performed better-assessing asthma control in children. Thus, although more validation studies are needed, we suggest its use in epidemiological studies to assess asthma control.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 9
Documents
We could not find any documents associated to the publication with allowed access.
Related Publications

Of the same journal

Traveling with food allergy: What to expect from the airlines? (2017)
Another Publication in an International Scientific Journal
Pádua, I.; Moreira, A; Padrão, Patrícia; Moreira, Pedro; Barros, Renata
The Editor recommends this issue's articles to the reader (2015)
Another Publication in an International Scientific Journal
Pereira, AM; Ahrens, B; Heijkenskjöld Rentzhog, C
Skin barrier dysfunction associates with type 2 inflammatory diseases: Evidence from a birth cohort (2024)
Another Publication in an International Scientific Journal
Abreu, DB; Mendes, FC; Silva, D; Barros, H; Moreira, A
Reply to Prof. Tiejuan Shao et al. (2025)
Another Publication in an International Scientific Journal
de Castro Mendes, F.; Severo, M.; Paciência, I.; Lopes, C.; Santos, A.C.; Barros, H.; Moreira, A.; Moreira, Pedro
Functional textiles for atopic dermatitis: a systematic review and meta-analysis (2013)
Another Publication in an International Scientific Journal
Lopes, C; Silva, D; Delgado, L; Correia, O; Moreira, André

See all (33)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-22 at 11:54:35 | Privacy Policy | Personal Data Protection Policy | Whistleblowing