Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Study and calibration of FBG sensors for the accurate strain monitoring of COPV
Publication

Publications

Study and calibration of FBG sensors for the accurate strain monitoring of COPV

Title
Study and calibration of FBG sensors for the accurate strain monitoring of COPV
Type
Article in International Conference Proceedings Book
Year
2012
Authors
Pereira, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Faria, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Frias, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Frazao, O
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Marques, AT
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
ECCM15 - 15TH EUROPEAN CONFERENCE ON COMPOSITE MATERIALS
Venice, Italy, 24-28 June
Indexing
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-009-NZW
Abstract (EN): In this research programme methodologies to improve the accuracy in the results measured with embedded fibre Bragg gratings (FBG) sensors were studied and implemented in order to produce a composite overwrapped pressure vessel (COPV) prototype that incorporate a non-destructive sensing technologies. Using a carbon/epoxy prepreg system, test specimens were manufactured with longitudinally embedded FBG sensors. The combined behaviour of the sensors and the host material was characterized and a calibration rule (correction factor) was determined for the chosen material. The consistency of the results with both theoretical and empirical assumptions suggests that the proposed method is applicable to a wide range of FBG sensors and host materials. In this paper, the experimental setup and procedure used to assess to the calibration rule is addressed and further detailed.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-15 at 20:58:48 | Privacy Policy | Personal Data Protection Policy | Whistleblowing