Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Comparison of Jamar and Bodygrip Dynamometers for Handgrip Strength Measurement
Publication

Publications

Comparison of Jamar and Bodygrip Dynamometers for Handgrip Strength Measurement

Title
Comparison of Jamar and Bodygrip Dynamometers for Handgrip Strength Measurement
Type
Article in International Scientific Journal
Year
2017
Authors
Guerra, RS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sousa, AS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fonseca, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pichel, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 31
Pages: 1931-1940
ISSN: 1064-8011
Other information
Authenticus ID: P-00N-7PP
Abstract (EN): Guerra, RS, Amaral, TF, Sousa, AS, Fonseca, I, Pichel, F, and Restivo, MT. Comparison of Jamar and Bodygrip dynamometers for handgrip strength measurement. J Strength Cond Res 31(7): 1931-1940, 2017-Studies that compared the agreement between Jamar and other models of dynamometers for handgrip strength (HGS) measurement have exhibited variability in the provided results. The lack of comparability between dynamometers led to the development of the Bodygrip dynamometer. This study aims to examine the reliability of the Bodygrip for HGS measurement, to compare it with the Jamar, and to explore the HGS differences between instruments considering the ergonomic effect of using the Bodygrip with 2 different handles. A cross-sectional study was conducted in free-living (n = 114, 18-89 years) and inpatient (n = 50, 65-93 years) volunteers. Nondominant HGS was tested randomly with the Jamar and Bodygrip, the latter using 2 different handles-curved and straight types. Handgrip strength was obtained for each participant under the same conditions. Each individual performed 2 HGS measurements with each dynamometer, and the maximum HGS value was considered for dynamometers comparison. Differences in the maximum HGS value between the 2 devices (Jamar-Bodygrip), intraclass correlation coefficients (ICCs), Bland and Altman plots, and limits of agreement were obtained. Correlation between the highest HGS measurement obtained for the nondominant hand with the Jamar and with the Bodygrip using each handle was excellent (ICCs: 0.93-0.95). Mean differences of-0.5 (limits of agreement:-4.6; 3.5) kgf with the curved handle and of 1.0 (-7.7; 9.7) kgf with the straight handle for the free-living participants were obtained, whereas for inpatients these values were-1.0 (-3.8; 1.9) kgf and 2.1 (-3.3; 7.5) kgf, respectively, for the curved and straight handles. The Bodygrip is comparable to the Jamar in free-living adults and in hospitalized older adults, exhibiting excellent interinstrument reliability. The Bodygrip with the curved handle produces results closer to the Jamar when compared with Bodygrip with the straight handle, which emphasizes the importance of grip handle ergonomics to measurement reliability. © 2016 National Strength and Conditioning Association.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Ventilatory and perceived ergogenic effects of mandibular forward repositioning during running at maximal oxygen uptake intensity (2025)
Article in International Scientific Journal
Cardoso, Filipa; Costa, Mário J.; Colaço, Paulo; Vilas-Boas, João Paulo; Pinho, João C.; Pyne, David B.; Fernandes, Ricardo J.
VALIDATION OF HEART RATE MONITOR POLAR RS800 FOR HEART RATE VARIABILITY ANALYSIS DURING EXERCISE (2018)
Article in International Scientific Journal
Hernando, David; Garatachea, Nuria; Almeida, R; Casajús, Jose Antonio; Bailón, Raquel
Using the rating of perceived exertion and heart rate to quantify training intensity in female soccer players: Validity and utility (2022)
Article in International Scientific Journal
Júlio A. Costa; João Brito; Fábio Y. Nakamura; Pedro Figueiredo; António Rebelo
TRAINING STATUS AND MATCH ACTIVITY OF PROFESSIONAL SOCCER PLAYERS THROUGHOUT A SEASON (2013)
Article in International Scientific Journal
Silva, JR; Magalhaes, J; Ascensao, A; Seabra, AF.; Rebelo, An
The arrowhead agility test: reliability, minimum detectable change, and practical applications in soccer players (2020)
Article in International Scientific Journal
Vincenzo Rago; João Brito; Pedro Figueiredo; Georgios Ermidis; Daniel Barreira; Antonio Rebelo

See all (27)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-06 at 10:59:44 | Privacy Policy | Personal Data Protection Policy | Whistleblowing