Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Automatic and semi-automatic approaches for arteriolar-to-venular computation in retinal photographs
Publication

Publications

Automatic and semi-automatic approaches for arteriolar-to-venular computation in retinal photographs

Title
Automatic and semi-automatic approaches for arteriolar-to-venular computation in retinal photographs
Type
Article in International Conference Proceedings Book
Year
2017
Authors
Ana Maria Mendonça
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Remeseiro, B
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Dashtbozorg, B
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Aurélio Campilho
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
Final page: 101341L
Conference on Medical Imaging - Computer-Aided Diagnosis
Orlando, FL, FEB 13-16, 2017
Other information
Authenticus ID: P-00M-G2E
Abstract (EN): The Arteriolar-to-Venular Ratio (AVR) is a popular dimensionless measure which allows the assessment of patients' condition for the early diagnosis of different diseases, including hypertension and diabetic retinopathy. This paper presents two new approaches for AVR computation in retinal photographs which include a sequence of automated processing steps: vessel segmentation, caliber measurement, optic disc segmentation, artery/vein classification, region of interest delineation, and AVR calculation. Both approaches have been tested on the INSPIRE-AVR dataset, and compared with a ground-truth provided by two medical specialists. The obtained results demonstrate the reliability of the fully automatic approach which provides AVR ratios very similar to at least one of the observers. Furthermore, the semi-automatic approach, which includes the manual modification of the artery/vein classification if needed, allows to significantly reduce the error to a level below the human error.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 7
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-09 at 22:08:08 | Privacy Policy | Personal Data Protection Policy | Whistleblowing