Precipitation titrations using an automatic titrator based on a multicommutated unsegmented flow system

Title
Precipitation titrations using an automatic titrator based on a multicommutated unsegmented flow system
Type
Article in International Scientific Journal
Year
2000
Authors
Almeida, CMNV
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Araujo, MCU
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Reis, BF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Zagatto, EAG
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: The AnalystImported from Authenticus Search for Journal Publications
Vol. 125
Pages: 333-340
ISSN: 0003-2654
Other information
Authenticus ID: P-001-140
Abstract (EN): An automatic flow titrator based on a multicommutated unsegmented flow system was used to perform precipitation titrations with potentiometric detection. The titration approach is based on sequential introduction of increasing titrant and decreasing titrand volumes into a mixing chamber. The system allows the attainment of complete curves, the titration end point being determined by the Gran method, as is usually employed in batch potentiometric titrations. The theoretical model for the analytical process is presented and discussed and the determination of titrand concentration is performed without any prior calibration. The automatic flow titrator developed was applied to chloride determination in bottled natural waters and the results obtained were reproducible (RSD 3.2 and 3.8% for repeatability and reproducibility, respectively) and in good agreement with those given by the reference procedure (relative deviation within the range from -4.6 to 4.8%).
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The role of ionic liquids in the biocatalytic evaluation of bisphenol levels as contaminant: an automatic approach (2018)
Article in International Scientific Journal
Costa, AR; Passos, MLC; Pinto, PCAG; Pereira, SAP; Lucia L M F S Saraiva
Stochastic detection and characterisation of individual ferrocene derivative tagged graphene nanoplatelets (2016)
Article in International Scientific Journal
Wu, HY; Lin, QW; Batchelor McAuley, C; Goncalves, LM; Lima, CFRAC; Compton, RG

See all (47)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-21 at 01:13:01 | Privacy Policy | Personal Data Protection Policy | Whistleblowing