Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > An automatic determination of caffeine in soft drinks using flow injection system with amperometric detection
Publication

Publications

An automatic determination of caffeine in soft drinks using flow injection system with amperometric detection

Title
An automatic determination of caffeine in soft drinks using flow injection system with amperometric detection
Type
Article in International Scientific Journal
Year
1998
Authors
Delerue Matos, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Nouws, HPA
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Vaz, MCVF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 15
Pages: 265-269
ISSN: 0265-203X
Publisher: Taylor & Francis
Other information
Authenticus ID: P-001-85W
Abstract (EN): An automatic procedure based on a flow injection analysis manifold has been developed for the determination of caffeine in soft drinks using amperometric detection (+1.70 V vs AgCl/Ag). The sample and standards were injected without pre-treatment, with a sampling rate of 120 determinations per hour. The determination of caffeine in several soft drinks available in Portugal using the developed automatic system provided results with mean recovery values between 98% and 103% and a mean standard deviation between 2% and 5%. The results obtained were compared with those given by the reference method recommended by AOAC. Relative deviation was always less than 4%. Reproducibility of the method was assessed by the relative standard deviation (RSD%), values of which were less than 2%.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Screening of grapes and wine for azoxystrobin, kresoxim-methyl fungicides by HPLC with diode array detection (2005)
Article in International Scientific Journal
Susana De Melo Abreu; Manuela Correia; Paulo Herbert; Lúcia Santos; Arminda Alves
Determination of acrylamide in coffee and coffee products by GC-MS using an improved SPE clean-up (2006)
Article in International Scientific Journal
Soares, C; Cunha, S; Fernandes, J
Antibiotic residues in edible tissues and antibiotic resistance of faecal Escherichia coli in pigs from Portugal (2004)
Article in International Scientific Journal
Pena, A; Serrano, C; Reu, C; Baeta, L; Calderon, V; Silveira, I; Sousa, JC; Peixe, L
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-15 at 00:56:38 | Privacy Policy | Personal Data Protection Policy | Whistleblowing