Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > An automatic titrator based on a multicommutated unsegmented flow system - Its application to acid-base titrations
Publication

Publications

An automatic titrator based on a multicommutated unsegmented flow system - Its application to acid-base titrations

Title
An automatic titrator based on a multicommutated unsegmented flow system - Its application to acid-base titrations
Type
Article in International Scientific Journal
Year
2000
Authors
Almeida, CMNV
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Zagatto, EAG
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Araujo, MCU
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 407
Pages: 213-223
ISSN: 0003-2670
Publisher: Elsevier
Other information
Authenticus ID: P-001-0SJ
Abstract (EN): A continuous flow methodology to perform acid-base titrations is described. The titrations are carried out on a multicommutated flow system which simulates batch titration procedures. The titration strategy is based on sequential insertion of increasing titrant and decreasing titrand volumes in a reactor, thus accomplishing complete titration curves. The assessment of the titration end point is similar to that of conventional batch procedures. The theoretical model for the determination of titrand concentration without requiring any calibration process is presented and discussed. The present system was evaluated in vinegar acidity determinations and provided an accuracy better than 3% with a good repeatability (relative standard deviation (RSD) = 2.5%; n = 10) and reproducibility (RSD < 5%). The titration accuracy is time-dependent and has been tested in the 2-10 min range.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 11
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Precipitation titrations using an automatic titrator based on a multicommutated unsegmented flow system (2000)
Article in International Scientific Journal
Almeida, CMNV; Araujo, MCU; Lapa, RAS; Lima, JLFC; Reis, BF; Zagatto, EAG

Of the same journal

Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS (1986)
Another Publication in an International Scientific Journal
ALONSO, J; BARTROLI, J; Lima, JLFC; MACHADO, AASC
Papers presented at the 10th International Conference on Flow Analysis Porto, Portugal, 3-8 September 2006 - Foreword (2007)
Another Publication in an International Scientific Journal
Purnendu Dasgupta; Jose L F C Lima; Lucia Saraiva; Marcela Segundo
Optical probes for detection and quantification of neutrophils' oxidative burst. A review (2009)
Another Publication in an International Scientific Journal
Marisa Freitas; Jose L F C Lima; Eduarda Fernandes
Nanoparticle-based assays in automated flow systems: A review (2015)
Another Publication in an International Scientific Journal
Marieta L C Passos; Paula C A G Pinto; Joao L M Santos; Lucia L M F S Saraiva; Andre R T S Araujo

See all (221)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-18 at 21:03:41 | Privacy Policy | Personal Data Protection Policy | Whistleblowing