Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > A FIA procedure for enzymatic determination of high glucose concentrations. Application to parenteral solutions analysis
Publication

Publications

A FIA procedure for enzymatic determination of high glucose concentrations. Application to parenteral solutions analysis

Title
A FIA procedure for enzymatic determination of high glucose concentrations. Application to parenteral solutions analysis
Type
Article in International Scientific Journal
Year
1999
Authors
Barrado, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vela, MH
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: AnalusisImported from Authenticus Search for Journal Publications
Vol. 27
Pages: 170-174
ISSN: 0365-4877
Publisher: EDP Sciences
Other information
Authenticus ID: P-001-4WP
Abstract (EN): A flow injection system for the determination of high levels of glucose in parenteral solutions based on amperometric detection of hydrogen peroxide produced in the glucose oxidase reaction was developed, The determinations were made without any sample pre-treatment. The flow injection manifold includes two dialysis units to perform dilution of the samples and to maintain the enzyme in a closed re-circulation loop. Due to the hydrodynamic characteristics of the analytical system, the variables were optimized using a parameter design of Taguchi. Under optimal conditions, a linear response for glucose concentrations, between 0.1 and 1.0 M was achieved. A good reproducibility (r.s.d. < 3%) and a sampling rate of 30 determinations/hour were observed. The results obtained are in a good agreement with those obtained using the spectrophotometric enzymatic method.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Sequential determination of calcium and magnesium cations in haemodialysis solutions by FIA (1997)
Article in International Scientific Journal
Lapa, RAS; Lima, JLFC; Vela, MH; Barrado, E
A FIA-enzymatic method for the determination of L(+) lactate: application in parenteral solution analysis (2000)
Article in International Scientific Journal
Barrado, E; Vela, MH; Lapa, RAS; Lima, JLFC

Of the same journal

Rapid spectrophotometric determination of nitrates and nitrites in marine aqueous culture media (1998)
Article in International Scientific Journal
Carvalho, AP; Meireles, LA; F. Xavier Malcata
Determination of nitrate in carbon black by flow injection analysis (FIA) with potentiometric detection (1997)
Article in International Scientific Journal
Canal, IG; Lima, JLFC; Montenegro, MCBSM; PrezOlmos, R
Determination of boric acid in nickel plating baths using a tetrafluoroborate selective electrode (1996)
Article in International Scientific Journal
PerezOlmos, R; Garcia, M; Etxebarria, MB; Lima, JLFC; Montenegro, MCBSM
Detecting information in gas sensor responses using analysis of variance (1998)
Article in International Scientific Journal
Nicolas, C; Barros, AS; Rutledge, DN; Hossenlopp, J; Trystram, G; Emonet, C

See all (11)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-09 at 11:27:26 | Privacy Policy | Personal Data Protection Policy | Whistleblowing