Respiratory rate estimation from multilead directions, based on ECG delineation

Title
Respiratory rate estimation from multilead directions, based on ECG delineation
Type
Article in International Conference Proceedings Book
Year
2016
Authors
Noriega, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Marañón, , E J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pérez, DR
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Orini, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Other information
Authenticus ID: P-00M-ZEJ
Abstract (EN): Estimating the instantaneous respiratory rate (Rr) from the electrocardiogram (ECG) is of interest as respiration direct measurement in clinical situations is often cumbersome. In this study, the Rr was estimated from the same Final Directions of maximum projection (FD) used for multi lead ECG automatic delineation. Power spectral analysis over the directions based on QRS complex main peak and T wave onset, peak and end spatial loops was used for Rr estimation. On a subset of the Physionet MGH/MF dataset, the proposed method yielded more accurate Rr estimates (minimum mean absolute error (MAE), 2.82 bpm) than the frequency tracking algorithm (minimum MAE, 4.53 bpm) and Fourier-based frequency estimation (minimum MAE, 4.94 bpm) using each lead alone, outperforming also the weighted multi-signal oscillator-based algorithm estimates for two or three lead (minimum MAE, 3.04 bpm). It was also shown that the FD of the three orthogonalized leads from Principal Component algorithm, improve the performance of Rr estimation.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4