Two, three, four or six telescopes with phase referencing or closure phase relations: the best tactics for interferometric image reconstruction

Title
Two, three, four or six telescopes with phase referencing or closure phase relations: the best tactics for interferometric image reconstruction
Type
Article in International Conference Proceedings Book
Year
2014
Authors
Gomes, N
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Thiebaut, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Conference on Optical and Infrared Interferometry IV
Montreal, CANADA, JUN 23-27, 2014
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00A-648
Abstract (EN): Two simulated astronomical objects (a star cluster, and a young stellar object) were mock observed with the VLTI for different array configurations and instruments, and their images reconstructed and compared. The aim of the work is to infer when/if phase referencing with less telescopes is a better choice over closure phases with more telescopes. Three scenarios were put under scrutiny: Phase Referencing (PhR) with 2 telescopes vs Closure Phase (CPh) with 3 telescopes, PhR with 3 telescopes vs CPh with 4 telescopes, and PhR with 4 telescopes vs CPh with 6 telescopes. The number of nights is kept fixed for a given PhR vs CPh configuration. The UV-coverage was improved for the PhR case, by uniformly paving the (u, v) plane while keeping fixed the total number of sampled spatial frequencies. For the majority of the configurations, the results point to comparable performances of phase referencing and closure phases, when the UV-space is judiciously chosen.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Assessing the quality of restored images in optical long-baseline interferometry (2017)
Article in International Scientific Journal
Gomes, N; P. J. V. Garcia; Thiebaut, E
Comparison between closure phase and phase referenced interferometric image reconstructions (2010)
Article in International Conference Proceedings Book
Gomes, N; P. J. V. Garcia; Thiebaut, E; Renard, S; Mercedes E Filho
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-09-29 at 00:47:18 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book