Você está em: Start > Publications > View > Crawler excavator track repair: Track fastening-noise characterization and personal protection
Publication

Publications

Crawler excavator track repair: Track fastening-noise characterization and personal protection

Title
Crawler excavator track repair: Track fastening-noise characterization and personal protection
Type
Article in International Conference Proceedings Book
Year
2014
Authors
Couto, NF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Castelo Branco, JC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
João Santos Baptista
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 517-522
10th Annual Congress of the Portuguese-Society-of-Occupational-Safety-and-Hygiene on Occupational Safety and Hygiene (SPOSHO)
Guimaraes, PORTUGAL, FEB 13-14, 2014
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-009-4E8
Abstract (EN): The heavy machinery maintenance activity sector is characterized by the occurrence of intense noise during the working shift. This noise evaluation in the workplace was conducted to assess the noise emission during the task of removing tracks from an excavator, and to characterize in detail the nature of the risk in the sense of controlling the workers exposure to occupational noise. The measurements were made according to both the Portuguese and international framework, a narrow band analysis was made to the noise using the 1/1 octave band analysis method. In the measurements the presence of high intensity noise levels was showed with frequencies above 1 kHz. It was recognized the advantage of using a double protection system consisting in the simultaneous use of earplugs and earmuffs, granting a continuous protection implementing the obligation of earplugs use and making earmuffs use compulsory. According to these findings, this practice became mandatory.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6