Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Effect of the generators tripping in the transient stability of an electrical power system using the extended equal area criteria
Publication

Publications

Effect of the generators tripping in the transient stability of an electrical power system using the extended equal area criteria

Title
Effect of the generators tripping in the transient stability of an electrical power system using the extended equal area criteria
Type
Article in International Conference Proceedings Book
Year
1998
Authors
Ferreira, CMM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pinto, JAD
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernando Maciel Barbosa
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
Pages: 1295-1299
1998 International Conference on Power System Technology (POWERCON 98)
BEIJING, PEOPLES R CHINA, AUG 18-21, 1998
Indexing
Other information
Authenticus ID: P-001-9G3
Abstract (EN): In this paper it is studied and analysed the transient stability of a test power network, considering the tripping of one or more generators. It was used the software package TRANsySTEM that the authors developed for transient security assessment of a multimachine power system. These computer programs use the extended equal area criteria formulation. The results obtained with this direct approach were compared with the solutions produced by the Runge-Kutta method. It is also analysed the influence of the sudden increase in the electromagnetic torque in the rotor shaft fatigue life of the remaining generators, when one or more power units are tripped. Finally, some conclusions that provide a valuable contribution to the understanding of the transient security assessment of a multimachine power system are pointed out.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Transient stability assessment of an electric power system using trajectory sensitivity analysis (2005)
Article in International Conference Proceedings Book
Ferreira, CMM; Pinto, JAD; Fernando Maciel Barbosa
Transient stability analysis of an electric power system using a combined Monte Carlo-extended equal area formulation (1997)
Article in International Conference Proceedings Book
Ferreira, CMM; Pinto, JAD; Fernando Maciel Barbosa
The rough set theory applied to the steady-state contingency classification (2005)
Article in International Conference Proceedings Book
Agreira, CIF; Ferreira, CMM; Pinto, JAD; Fernando Maciel Barbosa
On-line transient stability assessment of an electric power system using a dynamic hybrid extended equal area formulation (1999)
Article in International Conference Proceedings Book
Ferreira, CMM; Pinto, JAD; Fernando Maciel Barbosa
Influence of the under load tap changers on the dynamic voltage collapse of an electric power system (2005)
Article in International Conference Proceedings Book
Pereira, RMM; Ferreira, CMM; Pinto, JAD; Fernando Maciel Barbosa