Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Analysis of the generators tripping in the transient stability of an electrical power network using a hybrid method
Publication

Publications

Analysis of the generators tripping in the transient stability of an electrical power network using a hybrid method

Title
Analysis of the generators tripping in the transient stability of an electrical power network using a hybrid method
Type
Article in International Conference Proceedings Book
Year
2003
Authors
C. M. Machado Ferreira
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
J. A. Dias Pinto
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernando Maciel Barbosa
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
Pages: 152-155
UPEC 2003, 38th International Universities' Power Engineering Conference
Thessaloniki, 1 September 2003 through 3 September 2003
Indexing
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-007-CFX
Resumo (PT):
Abstract (EN): In this paper it is used a hybrid approach to study and analyse the tripping effect of one or more generators in the transient stability of a multimachine power system. This efficient and robust approach combines the advantages of the time domain integration schemes to compute the initial system trajectory with the equal area criterion. The transient stability assessment is obtained using stability indices. Consequently, the time domain simulation is only computed during a short integration period. This early termination procedure reduces drastically the computing time. The software package TRANsySTEM developed by the authors was applied to a multimachine test power network. The results obtained with this hybrid formulation were compared with the solutions produced by a time domain simulation program. Finally, some conclusions that provide a valuable contribution to the understanding of the generators tripping effect in the transient stability problem are pointed out.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Transient stability assessment of an electric power system using trajectory sensitivity analysis (2004)
Article in International Conference Proceedings Book
C. M. Machado Ferreira; J. A. Dias Pinto; Fernando Maciel Barbosa
The Rough Set Theory applied to the steady - State contingency classification (2004)
Article in International Conference Proceedings Book
C. I. Faustino Agreira; C. M. Machado Ferreira; J. A. Dias Pinto; Fernando Maciel Barbosa
Steady-state contingency classification using the rough set theory (2003)
Article in International Conference Proceedings Book
C. I. Faustino Agreira; C. M. Machado Ferreira; J. A. Dias Pinto; Fernando Maciel Barbosa
Selective load shedding in the dynamic voltage stability assessment of an electric power system (2003)
Article in International Conference Proceedings Book
R. M. Monteiro Pereira; C. M. Machado Ferreira; J. A. Dias Pinto; Fernando Maciel Barbosa
Influence of the under load tap changers on the dynamic voltage collapse of an electric power system (2004)
Article in International Conference Proceedings Book
R. M. Monteiro Pereira; C. M. Machado Ferreira; J. A. Dias Pinto; Fernando Maciel Barbosa

See all (7)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-26 at 00:24:51 | Privacy Policy | Personal Data Protection Policy | Whistleblowing