Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Calibration of Bi-planar Radiography with a Rangefinder and a Small Calibration Object
Publication

Publications

Calibration of Bi-planar Radiography with a Rangefinder and a Small Calibration Object

Title
Calibration of Bi-planar Radiography with a Rangefinder and a Small Calibration Object
Type
Article in International Conference Proceedings Book
Year
2008
Authors
Daniel Cardoso de Moura
(Author)
Other
Jorge Manuel Gomes Barbosa
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
João Manuel R. S. Tavares
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Reis, AM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 572-581
4th International Symposium on Visual Computing
Las Vegas, NV, DEC 01-03, 2008
Other information
Authenticus ID: P-007-QRT
Abstract (EN): In this paper we propose a method for geometrical calibration of bi-planar radiography that aims at minimising the impact of calibration objects on the content of radiographs, while remaining affordable. For accomplishing this goal, we propose a small extension to conventional imaging systems: a low-cost rangefinder that enables to estimate some of the geometrical parameters. Even with this extension; a small calibration object is needed for correcting scale. The proposed method was tested on 17 pairs of radiographs of a phantom object of known dimensions. For calculating scale; only a reference distance of 40mm was used. Results show a RMS error of 0.36mm with 99% of the errors inferior to 0.85mm. We conclude that the method presented here performs robustly and achieves sub-millimetric accuracy, while remaining affordable and requiring only two radiopaque marks visible in radiographs.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-17 at 04:19:06 | Privacy Policy | Personal Data Protection Policy | Whistleblowing