Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Optimal design of grounding system in transmission line
Publication

Publications

Optimal design of grounding system in transmission line

Title
Optimal design of grounding system in transmission line
Type
Article in International Conference Proceedings Book
Year
2007
Authors
Khodr, HM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Machado e Moura, AME
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vladimiro Miranda
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
Pages: 280-288
14th International Conference on Intelligent System Applications to Power Systems (ISAP 2007)
Kaohsiung, TAIWAN, NOV 04-08, 2007
Indexing
Other information
Authenticus ID: P-004-F70
Abstract (EN): A novel optimization methodology is proposed for the design of transmission line grounding systems, taking into account technical as well as economical considerations. The problem of designing the grounding systems of transmission fines is stated as a linear-integer programming problem in terms of the construction characteristics and the particular requirements of the tower grounding schemes at the supports of each of the different line sections, in order to minimize the variable investment costs, subject to the maximum allowed line outage rate due to the lightning activity. The mathematical statement of the problem allows solutions in which the transmission tower footing resistance changes along the line, depending on the cost and on the particular characteristics of each tower grounding, assuring however, that the average behavior enforces the desired outage rate due to lightning activity, selecting the complementary electrode scheme required at each tower. The methodology is tested on a real case consisting of a 230 kV transmission line, 85.4 Km long, with 180 towers. The linear programming branch and bound mathematical technique was applied for the solution of the test case. Two different simulation approaches for the calculation of the behavior of the fine subject to lightning phenomena were evaluated without loss of generality: the approach proposed in [1], selected as an initial test due to its simplicity, and the improved version presented in [2]. Results are presented and compared to the design obtained through conventional tower design approaches with important reductions in the investment costs, encouraging the use and further development of the methodology.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 9