Photoplethysmographic Logger with Contact Force and Hydrostatic Pressure Monitoring

Title
Photoplethysmographic Logger with Contact Force and Hydrostatic Pressure Monitoring
Type
Article in International Conference Proceedings Book
Year
2013
Authors
Pedro Santos
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vania Almeida
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Joao Cardoso
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Carlos Correia
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Conference proceedings International
3rd Portuguese Bioengineering Meeting
Braga, PORTUGAL, FEB 20-23, 2013
Indexing
Scientific classification
FOS: Engineering and technology > Environmental biotechnology
Other information
Authenticus ID: P-006-FJ4
Abstract (EN): Oxygen saturation is a key parameter for assessing a patient condition. The present work aims to develop a stand-alone pulse oximeter and photo plethysmographic system. In addition, it incorporates a force sensor and a set of accelerometers to measure the contact force and the finger height offset relatively to the heart. Both the design of hardware and the development of firmware are presented. Currently, the system is able to retrieve a stable photoplethysmographic waveform and compute the oxygen saturation in real time. Signals acquired in a healthy subject led to a value of 91.5 +/- 1.1%. Both the height offset of the finger and the contact force between the finger and the probe proved to have influence in the photoplethysmographic waveform as well as in the oxygen saturation results.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-13 at 03:42:06 | Privacy Policy | Personal Data Protection Policy | Whistleblowing