Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters
Publication

Publications

Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters

Title
Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters
Type
Article in International Scientific Journal
Year
2013
Authors
Karolina Skraskova
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lucia H M L M Santos
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Dalibor Satinsky
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Angelina Pena
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Maria Conceicao B S M Montenegro
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Petr Solich
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lucie Novakova
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 927
Pages: 201-208
ISSN: 1570-0232
Publisher: Elsevier
Scientific classification
FOS: Natural sciences > Chemical sciences
Other information
Authenticus ID: P-005-0QK
Abstract (EN): In this paper two fast and highly sensitive ultra-high performance liquid chromatography (UHPLC) methods for the determination of tetracycline antibiotics (oxytetracycline, tetracycline, doxycycline, demeclocycline, chlortetracycline, minocycline and degradation product epitetracycline) in surface waters have been developed using fluorescence (FL) and mass spectrometry (MS) detection. ACQUITY UPLC BEH C8 and ACQUITY CSH C18 columns were employed for FL and MS detection, respectively, both packed with 1.7 mu m particles. Mixed-mode separation mechanism of CSH (charged surface technology) sorbent was found particularly useful in analysis of TCs, which possess problematic amphoteric structures. The FL methodology was based on chelation of tetracyclines with calcium ions to perform on-column derivatisation. The developed methods were compared in the terms of validation parameters including linearity, sensitivity, precision and accuracy. The linearity range for FL detection was within 7 ng mL(-1) to 50 mu g mL(-1) with method limit of detection (MLOD) as low as 0.2 ng mL(-1) for most of the analytes. MS detection showed even higher sensitivity reaching MLOD of 0.003 ngmL(-1), which is the highest sensitivity reported so far in analysis of TCs. Matrix matched calibration curves in the range of 0.01-50 ng mL(-1) were used for quantification to compensate for matrix effects with the correlation coefficients demonstrating good linearity (0.9940-0.9999). The extraction of the antibiotics from surface waters was performed using solid phase extraction with Oasis HLB cartridges. Accuracy was expressed as recovery with values ranging from 96.52% to 127.30% and from 91.66% to 123.70% for FL and MS detection, respectively.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The relationship between Candida species charge density and chitosan activity evaluated by ion-exchange chromatography (2011)
Article in International Scientific Journal
Palmeira de Oliveira, A; Passarinha, LA; Gaspar, C; Palmeira de Oliveira, R; Sarmento, B; Martinez de Oliveira, J; pina-vaz, c; rodrigues, ag; Queiroz, JA
Separation of human immunoglobulin G subclasses on a protein A monolith column (2014)
Article in International Scientific Journal
Pelin Leblebici ; M. Enis Leblebici; Frederico Ferreira da Silva; Alírio E. Rodrigues; Luís S. Pais
Sample preparation and chromatographic methods for the determination of protein-bound uremic retention solutes in human biological samples: An overview (2023)
Article in International Scientific Journal
Fernandes, SR; Meireles, AN; Marques, SS; Silva, L; Luisa Barreiros; Benedita Sampaio-Maia; Miro, M; Marcela A Segundo
Quantification of doping compounds in faecal samples from racing pigeons, by liquid chromatography-tandem mass spectrometry (2018)
Article in International Scientific Journal
Moreira, FX; Silva, R; Andre, MB; de Pinho, PG; Maria de Lourdes Bastos; Ruivo, J; Ruivo, P; Helena Carmo
Quantification of alpha-amanitin in biological samples by HPLC using simultaneous UV- diode array and electrochemical detection (2015)
Article in International Scientific Journal
Juliana Garcia; Vera M Costa; Paula Baptista; Maria de Lourdes Bastos; Felix Carvalho

See all (17)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-30 at 15:38:27 | Privacy Policy | Personal Data Protection Policy | Whistleblowing