Increasing the torque transducer sensitivity of an RPA 2000 by a factor 5-10 using advanced data acquisition

Title
Increasing the torque transducer sensitivity of an RPA 2000 by a factor 5-10 using advanced data acquisition
Type
Article in International Scientific Journal
Year
2004
Authors
Loic Hilliou
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
D. van Dusschoten
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
M. Wilhelm
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
H. Burhin
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
E. R. Rodger
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 77 No. 1
Pages: 192-200
ISSN: 0035-9475
Scientific classification
FOS: Engineering and technology
Other information
Resumo (PT):
Abstract (EN): The sensitivity of an RPA 2000 under oscillatory shear conditions can be extended by a factor of 5 – 10 into the low torque region. This increases the overall dynamic range of this robust industrial instrument to 5 decades. This dynamic range is close to that of rheometers used in academic environments. This increased sensitivity is not a result of mechanical improvement, but the result of an advanced, but straight forward, data treatment of the raw torque transducer output in the time domain using “on the fly” averaging. This method is possible through the availability of modern ADC-cards. The underlying ideas of this averaging procedure, together with experimental verification on polyethylene are described in detail.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 9
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-09 at 10:05:12 | Privacy Policy | Personal Data Protection Policy | Whistleblowing