Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
Mapa das Instalações
Ed. Principal Ed. Principal Ed. Principal

Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD

Título
Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
Tipo
Artigo em Revista Científica Internacional
Ano
2016
Autores
Marques, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Cruz, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Quina, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Regencio, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Jacome, C
(Autor)
Outra
Revista
A Revista está pendente de validação pelos Serviços Administrativos.
Vol. 13
Páginas: 279-287
ISSN: 1541-2555
Outras Informações
ID Authenticus: P-00K-FQ9
Abstract (EN): This study aimed to determine the interrater and intrarater reliability and agreement and the minimal detectable change (MDC) of the Timed Up & Go (TUG) test and the 10-Meter Walk Test (10MWT) in older patients with Chronic Obstructive Pulmonary Disease (COPD). Patients (>= 60 years old) living in the community were asked to attend 2 sessions with 48-72-hour interval. In session 1, participants completed the TUG and 10MWT twice (2 trials) and were assessed by 2 raters. In session 2, they repeated the tests twice and were assessed by 1 rater. Interrater and intrarater reliability were calculated for the exact scores (using data from trial 1) and mean scores (mean of 2 trials) using Intraclass Correlation Coefficients (ICC2,1 and ICC2,2, respectively). Interrater and intrarater agreement were explored with the Bland & Altman method. The MDC95 was calculated from the standard error of measurement. Sixty participants (72.43 +/- 6.90 years old) completed session 1 and 41 participants session 2. Excellent ICC values were found for the TUG test (interrater: ICC2,1 = 0.997 ICC2,2 = 0.999; intrarater: ICC2,1 = 0.921 ICC2,2 = 0.964) and 10MWT (interrater: ICC2,1 = 0.992 ICC2,2 = 0.997; intrarater: ICC2,1 = 0.903 ICC2,2 = 0.946). Good interrater and intrarater agreement was also found for both tests. The MDC95 was 2.68 s and 1.84 s for the TUG and 0.40 m/s and 0.30 m/s for the 10MWT considering the exact and mean scores, respectively. Findings suggest that the TUG test and the 10MWT are reliable and have acceptable measurement error. Therefore, these measures may be used to assess functional balance (TUG) and gait (10MWT) deficits in older patients with COPD.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Minimal Clinically Important Difference for Quadriceps Muscle Strength in People with COPD following Pulmonary Rehabilitation (2021)
Artigo em Revista Científica Internacional
Oliveira, A; Rebelo, P; Paixao, C; Jacome, C; Cruz, J; Martins, V; Simao, P; Brooks, D; Marques, A
Global Functioning of COPD Patients With and Without Functional Balance Impairment: An Exploratory Analysis Based on the ICF Framework (2015)
Artigo em Revista Científica Internacional
Cruz, J; Marques, A; Jacome, C; Gabriel, R; Figueiredo, D
Computerized Respiratory Sounds in Patients with COPD: A Systematic Review (2015)
Artigo em Revista Científica Internacional
Jacome, C; Marques, A
Recomendar Página Voltar ao Topo
Copyright 1996-2026 © Faculdade de Desporto da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2026-02-17 às 16:08:12 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico